Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorTorres, Andre
dc.contributor.authorKovařík, Karel
dc.contributor.authorMarkovič, Tomáš
dc.contributor.authorAdámek, Jiří
dc.contributor.authorDuraň, Ivan
dc.contributor.authorEllis, Robert
dc.contributor.authorJeřáb, Martin
dc.contributor.authorŘeboun, Jan
dc.contributor.authorTurjanica, Pavel
dc.contributor.authorWeinzettl, Vladimír
dc.contributor.authorFernandes, Horacio
dc.date.accessioned2021-08-16T10:00:17Z-
dc.date.available2021-08-16T10:00:17Z-
dc.date.issued2021
dc.identifier.citationTORRES, A., KOVAŘÍK, K., MARKOVIČ, T., ADÁMEK, J., DURAŇ, I., ELLIS, R., JEŘÁB, M., ŘEBOUN, J., TURJANICA, P., WEINZETTL, V., FERNANDES, H. Test bench for calibration of magnetic field sensor prototypes for COMPASS-u tokamak. Fusion engineering and design, 2021, roč. 168, č. July 2021, s. 1-5. ISSN 0920-3796.cs
dc.identifier.issn0920-3796
dc.identifier.uri2-s2.0-85102246506
dc.identifier.urihttp://hdl.handle.net/11025/44920
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesFusion Engineering And Designen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Elsevieren
dc.titleTest bench for calibration of magnetic field sensor prototypes for COMPASS-u tokamaken
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedMagnetic field sensors are fundamental for control and physics exploitation of fusion devices. Their inductive nature implies high dynamic ranges and a broad bandwidth, thus a precise characterization and calibration of these probes is paramount. COMPASS-U will have a completely new set of magnetic diagnostics, from sensors to data acquisition. Sensors installed in-vessel will operate at 300–500 ◦C and should survive transients of even higher temperatures and thus materials used should be high-temperature compatible. These design limitations will have an impact on the dynamic range and bandwidth of the sensors, which needs to be reliably quantified, optimally with the same test bench for all sensor types. The first part of this work presents a test bench and the process of how to calibrate the effective area using a large solenoidal coil and frequency response of the magnetic sensor prototypes with a Helmholtz coil. In the second part, test results of the sensor prototypes are presented and discussed in detail. The low-bandwidth sensors made of mineral insulated cable (MIC), intended for plasma control and machine protection, show negligible attenuation up to 10 kHz, sufficient for their role. For fast coils consisting of bare wire wound on ceramic mandrel and Thick Printed Copper (TPC) sensors the negligible attenuation measured below 1 MHz is again sufficient for their intended purpose of detecting fast coherent plasma fluctuations. Resonances introduced by the capacitance of long cables from the vacuum vessel feedthroughs to the data acquisition systems are measured, to model their influence on the signal.en
dc.subject.translatedmagnetic diagnosticen
dc.subject.translatedmagneticsen
dc.subject.translatedTokamaken
dc.subject.translatedmineral insulated cablesen
dc.subject.translatedMICen
dc.subject.translatedmagnetic sensorsen
dc.subject.translatedfrequency responseen
dc.identifier.doi10.1016/j.fusengdes.2021.112467
dc.type.statusPeer-revieweden
dc.identifier.document-number670076200004
dc.identifier.obd43932938
Vyskytuje se v kolekcích:Články / Articles (KET)
Články / Articles (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Reboun_1-s2.0-S092037962100243X-main-1.pdf2,36 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/44920

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD