Název: In-situ monitoring method for curing of pastes used in printed electronics
Autoři: Janda, Martin
Pretl, Silvan
Řeboun, Jan
Citace zdrojového dokumentu: JANDA, M. PRETL, S. ŘEBOUN, J. In-situ monitoring method for curing of pastes used in printed electronics. In 2021 44th International Spring Seminar on Electronics Technology : /proceedings/. Piscaway: IEEE, 2021. s. 1-5. ISBN: 978-1-66541-477-7
Datum vydání: 2021
Nakladatel: IEEE
Typ dokumentu: konferenční příspěvek
ConferenceObject
URI: 2-s2.0-85113934387
http://hdl.handle.net/11025/49727
ISBN: 978-1-66541-477-7
Klíčová slova v dalším jazyce: printed electronics;conductive paste;dispensing;curing
Abstrakt: In this paper, a method for in-situ monitoring of curing of materials for printed electronics applications is introduced. Materials for printed electronics in form of inks and pastes need to be cured after printing. Curing is an important post-printing process. Curing is often done at elevated temperatures. The presented method includes a printable layout for conductive inks. The layout represents a large-area application and can be easily inspected by microscopy. The method also includes a specially designed holding frame that holds samples in the air and connects them to the measuring device. During curing the electrical resistance of the printed layout is measured. Presented results show that the curing process can be optimized by changing curing parameters like temperature and time, which is critical for substrates with low heat resistance.
Abstrakt v dalším jazyce: In this paper, a method for in-situ monitoring of curing of materials for printed electronics applications is introduced. Materials for printed electronics in form of inks and pastes need to be cured after printing. Curing is an important post-printing process. Curing is often done at elevated temperatures. The presented method includes a printable layout for conductive inks. The layout represents a large-area application and can be easily inspected by microscopy. The method also includes a specially designed holding frame that holds samples in the air and connects them to the measuring device. During curing the electrical resistance of the printed layout is measured. Presented results show that the curing process can be optimized by changing curing parameters like temperature and time, which is critical for substrates with low heat resistance.
Práva: Plný text je přístupný v rámci univerzity přihlášeným uživatelům.
© IEEE
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference Papers (KET)
Konferenční příspěvky / Conference papers (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Janda_09467541.pdf3,84 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/49727

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD