Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.advisor | Soukup, Radek | |
dc.contributor.author | Hovorka, Jan | |
dc.contributor.referee | Řeboun, Jan | |
dc.date.accepted | 2015-06-02 | |
dc.date.accessioned | 2016-03-15T08:50:40Z | |
dc.date.available | 2014-10-15 | cs |
dc.date.available | 2016-03-15T08:50:40Z | |
dc.date.issued | 2015 | |
dc.date.submitted | 2015-05-11 | |
dc.identifier | 62777 | |
dc.identifier.uri | http://hdl.handle.net/11025/18902 | |
dc.description.abstract | Diplomová práce se zabývá měřením dechové frekvence za pomocí smart textilií. V textu jsou zmapovány současné technologie smart textilií pro měření dechové frekvence. Tyto technologie jsou podrobně popsány a porovnány mezi sebou. V praktické části je navržen model pro měření dechové frekvence a zhodnocena přesnost měření. V závěru diplomové práce jsou získané hodnoty kriticky zhodnoceny. | cs |
dc.format | 54 s. (53 163 znaků) | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | cs | cs |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.rights | Plný text práce je přístupný bez omezení. | cs |
dc.subject | dechová frekvence | cs |
dc.subject | textilní elektrody | cs |
dc.subject | smart textilie | cs |
dc.subject | ekg | cs |
dc.subject | tenzometr | cs |
dc.subject | pletysmografie | cs |
dc.subject | pulsní oxymetr | cs |
dc.subject | akcelerometr | cs |
dc.title | Měření dechové frekvence aplikovatelné ve smart textiliích | cs |
dc.title.alternative | Respiratory Rate Measurement for Smart Textile Applications | en |
dc.type | diplomová práce | cs |
dc.thesis.degree-name | Ing. | cs |
dc.thesis.degree-level | Navazující | cs |
dc.thesis.degree-grantor | Západočeská univerzita v Plzni. Fakulta elektrotechnická | cs |
dc.thesis.degree-program | Elektrotechnika a informatika | cs |
dc.description.result | Obhájeno | cs |
dc.rights.access | openAccess | en |
dc.description.abstract-translated | Diploma thesis deals with measuring of the respiration rate by means of smart textiles. The technology smart textiles for measuring respiratory rate is described in this text. These technologies are described in detail and compared with each other. In the practical part the model for measuring respiratory rate is designed and the accuracy of the measurement is evaluated. In conclusion, the thesis are the values critically evaluated. | en |
dc.subject.translated | respiratory rate | en |
dc.subject.translated | textile electrodes | en |
dc.subject.translated | smart textiles | en |
dc.subject.translated | ekg | en |
dc.subject.translated | strain gauge | en |
dc.subject.translated | plethysmography | en |
dc.subject.translated | pulse oximeter | en |
dc.subject.translated | accelerometer | en |
Vyskytuje se v kolekcích: | Diplomové práce / Theses (KET) |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Mereni dechove frekvence aplikovatelne ve smart textiliich.pdf | Plný text práce | 3,57 MB | Adobe PDF | Zobrazit/otevřít |
vedouci-062777_vedouci.pdf | Posudek vedoucího práce | 391,76 kB | Adobe PDF | Zobrazit/otevřít |
oponent-062777_oponent.pdf | Posudek oponenta práce | 346,22 kB | Adobe PDF | Zobrazit/otevřít |
obhajoba-062777_hodnoceni.pdf | Průběh obhajoby práce | 170,61 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/18902
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.