Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Schmidt, H. P. | |
dc.contributor.editor | Mühlbacher, Jan | |
dc.date.accessioned | 2017-02-23T07:50:13Z | |
dc.date.available | 2017-02-23T07:50:13Z | |
dc.date.issued | 2005 | |
dc.identifier.citation | Proceedings of the Intensive Programme 2005. 1st ed. Pilsen: University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering, 2005, s. [24-34]. ISBN 80-7043-371-X. | en |
dc.identifier.isbn | 80-7043-371-X | |
dc.identifier.uri | http://home.zcu.cz/~tesarova/IP/Proceedings/Proc_2005/index.htm | |
dc.identifier.uri | http://hdl.handle.net/11025/25353 | |
dc.format | 11 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering | en |
dc.rights | © University of West Bohemia | en |
dc.subject | fotovoltaické systémy | cs |
dc.subject | plochý kabel | cs |
dc.subject | vícejádrový kabel | cs |
dc.subject | limit tepelného přetížení | cs |
dc.title | Optimal utilization of power buses for photovoltaic installations | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | In photovoltaic systems economic wiring can results in remarkable savings. A technique so far used in electrical systems of buildings and factories is the power bus with piercing contacts. A flat cable - the so called power bus - is installed as one single cable run. The electrical connections are carried out via plugs and sockets, which are clamped onto the flat cable. The electrical connection of the cores is done by piercing contacts. Multi core cables are used to reduce installation costs. With the application to photovoltaic systems the thermal overload limit is off special interest. | en |
dc.subject.translated | photovoltaic systems | en |
dc.subject.translated | flat cable | en |
dc.subject.translated | multi core cable | en |
dc.subject.translated | thermal overload limit | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Proceedings of the intensive programme 2005 Proceedings of the intensive programme 2005 |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Schmidt.pdf | Plný text | 4,5 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/25353
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.