dc.identifier.citationVAVRINSKÝ, E., SVOBODOVÁ, H., MIKOLÁŠEK., M., TVAROŽEK, V., KOVÁČ, J., ŠUTTA, P., MATEJOVIC, M., SEDLAK, S., KOPÁNI, M., ZAVODNIK, T., DONOVAL, M. Electro - optical monitoring of trisodium citrate applicable in haemodialysis. In ASDAM 2018 - Proceedings: 12th International Conference on Advanced Semiconductor Devices and Microsystems. Smolenice: Institute of Electrical and Electronics Engineers Inc., 2018. s. nestránkováno. ISBN 978-1-5386-7488-8.en
dc.identifier.isbn978-1-5386-7488-8
dc.identifier.uri2-s2.0-85059979548
dc.identifier.urihttp://hdl.handle.net/11025/31207
dc.description.abstractV této práci se popisují naše počáteční experimenty ve vývoji „on-line“ senzoru na monitoring koncentrace citrátu sodného (Na3C6H2O7) v mimo mozkovém proudění krve v průběhu hemodialýzy. Přesný a rychlý monitoring by umožnil regulaci koncentrace citrátu a návrat do krevního řečiště těla v jeho původních hodnotách, tím pacienta významně méně zatíženého než v přítomnosti. Nedávno jsme se soustředili na stanovení koncentrace měřením elektrické impedance a odrazivosti ve zkoumané krvi. Našim cílem je zkoumat trendy vlivu těchto signálů na koncentraci a vyvinout vhodnou metodiku, která může být použita později v senzorech. Částečně začínáme pracovat také na citlivosti metodiky, přičemž bychom rádi výpočtem dosáhli ekvivalentní elektrický model řešení. To je založeno na elektrochemickém dvouvrstvém modelu a korespondenci s Cole-Cole grafycs
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en
dc.relation.ispartofseriesASDAM 2018 - Proceedings: 12th International Conference on Advanced Semiconductor Devices and Microsystemsen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Institute of Electrical and Electronics Engineers Inc.en
dc.subjectCitrát sodnýcs
dc.subjecthemodialýzacs
dc.titleElectro - optical monitoring of trisodium citrate applicable in haemodialysisen
dc.title.alternativeElektro – optický monitoring citrátu sodného aplikovatelného v hemodialýzecs
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedIn this paper, we describe our initial steps in the development of online sensor to monitor the tri-sodium citrate concentration in extra-cerebral blood flow during haemodialysis. Accurate and fast monitoring would allow the regulation of the concentration of citrate returning to the human bloodstream to its original values, thereby, making the patient significantly less burdened than at present. In the early stages, we focused on the determination of concentration by measuring of electrical impedance and reflection in the collected blood. Our aim is to study the trends of influencing these signals by concentration and to develop a suitable methodology that can be used later in the sensor. In part, we begin working on the selectivity of the methodology that we would like to achieve by calculating the equivalent electrical model of the solution. It is based on the electrochemical double layer model and the corresponding Cole-Cole graphs.en
dc.subject.translatedTri-sodium citrateen
dc.subject.translatedhaemodialysisen
dc.identifier.doi10.1109/ASDAM.2018.8544574
dc.type.statusPeer-revieweden
dc.identifier.obd43925226
dc.project.IDED2.1.00/03.0088/CENTEM - Centrum nových technologií a materiálůcs
dc.project.IDLO1402/CENTEM+cs
Appears in Collections:Konferenční příspěvky / Conference Papers (KFY)
OBD

Files in This Item:
File SizeFormat 
Sutta_ASDAM 2018.pdf249,4 kBAdobe PDFView/Open    Request a copy


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/31207

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD