Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Oueslati, Chaima | |
dc.contributor.author | Mabrouk, Sabra | |
dc.contributor.author | Ghorbel, Faouzi | |
dc.contributor.author | Hedi Bedoui, Mohamed | |
dc.contributor.editor | Skala, Václav | |
dc.date.accessioned | 2019-05-14T05:18:43Z | - |
dc.date.available | 2019-05-14T05:18:43Z | - |
dc.date.issued | 2018 | |
dc.identifier.citation | WSCG '2018: short communications proceedings: The 26th International Conference in Central Europe on Computer Graphics, Visualization and Computer Vision 2016 in co-operation with EUROGRAPHICS: University of West Bohemia, Plzen, Czech Republic May 28 - June 1 2018, p. 64-69. | en |
dc.identifier.isbn | 978-80-86943-41-1 | |
dc.identifier.issn | 2464-4617 | |
dc.identifier.uri | wscg.zcu.cz/WSCG2018/!!_CSRN-2802.pdf | |
dc.identifier.uri | http://hdl.handle.net/11025/34657 | |
dc.description.abstract | X-ray angiography has been an effective modality for diagnosing coronary artery disease representing one of the leading causes of death. A 3D reconstruction of the coronary arteries is a very important step to facilitate the interpretation of angiograms. In this paper, we propose a 3D reconstruction method of the coronary arteries. In order to improve the pairwise matching performance of our approach, we introduce artificial interest points (nodes) to respect the topology variation between 3D vascular trees. New similarity measures are proposed to take into consideration the non-rigid coronary artery movement. To measure the performance of the proposed method, we evaluate the proposed method on clinical data. Results show that accuracy of vessel centerlines has the average projection error equal to 0.5 mm for 28 different patients. | en |
dc.format | 6 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Václav Skala - UNION Agency | en |
dc.relation.ispartofseries | WSCG '2018: short communications proceedings | en |
dc.rights | © Václav Skala - UNION Agency | cs |
dc.subject | rentgenová angiografie | cs |
dc.subject | 3D rekonstrukce | cs |
dc.subject | 3D cévní stromy | cs |
dc.subject | umělé uzliny | cs |
dc.title | 3D reconstruction of coronary arteries from rotational X-ray angiography | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.subject.translated | X-ray angiography | en |
dc.subject.translated | 3D reconstruction | en |
dc.subject.translated | 3D vascular trees | en |
dc.subject.translated | artificial nodes | en |
dc.identifier.doi | https://doi.org/10.24132/CSRN.2018.2802.9 | |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | WSCG '2018: Short Papers Proceedings |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Oueslati.pdf | Plný text | 874,6 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/34657