Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorTesařová, Miloslava
dc.contributor.authorKašpírek, Martin
dc.date.accessioned2019-10-28T11:00:12Z-
dc.date.available2019-10-28T11:00:12Z-
dc.date.issued2019
dc.identifier.citationTESAŘOVÁ, M., KAŠPÍREK, M. Evaluation of short interruptions of supply voltage in distribution system. In: Proceedings of the 10th International Scientific Symposium on Electrical Power Engineering (ELEKTROENERGETIKA 2019). Košice: Technical University of Košice, 2019. s. 111-115. ISBN 978-80-553-3324-3.en
dc.identifier.isbn978-80-553-3324-3
dc.identifier.uri2-s2.0-85070256019
dc.identifier.urihttp://hdl.handle.net/11025/35698
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherTechnical University of Košiceen
dc.relation.ispartofseriesProceedings of the 10th International Scientific Symposium on Electrical Power Engineering (ELEKTROENERGETIKA 2019)en
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Technical University of Košiceen
dc.titleEvaluation of short interruptions of supply voltage in distribution systemen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedContinuity of supply can be regulated by a national regulation authority to maintain or improve its level. Short interruptions are monitored and regulated much less frequently than long interruptions. They can occur as single event or in sequences cased by a single power system event or by independent events. Frequency of their occurrence is mainly characterized by the indicator MAIFI. Method used for counting interruption sequences greatly affects the values of the indicator. In regulatory framework, it is important to define continuity of supply indicators and to establish procedures for counting of interruptions. The presented work is initial step in preparation of methodology for MAIFI calculation in the Czech Republic. In the paper, long-term monitoring of events in selected MV/LV substations is evaluated. Number and percentage of short and long interruptions during monitoring period is shown. Values of MAIFI indicator are compared with values of modified indicator that besides short interruptions includes also severe voltage dips. The effect of various aggregation methods and time-aggregation intervals for counting of short interruptions is illustrated on the case of a MV/LV substation with extreme occurrence of short interruptions.en
dc.subject.translateddistribution systemen
dc.subject.translatedpower qualityen
dc.subject.translatedcontinuity of supplyen
dc.subject.translatedvoltage qualityen
dc.subject.translatedinterruptionen
dc.subject.translatedaggregationen
dc.type.statusPeer-revieweden
dc.identifier.obd43926995
dc.project.IDSGS-2018-023/Analýza a vyhodnocení dodávky elektrické energie simulací a modelováním pro dodržení optimálních spolehlivostních a kvalitativních parametrů, s respektováním integrace nových distribuovaných a obnovitelných zdrojů do elektrizační soustavy i odpovídající akumulace, při využití nových, pokročilých metod teoretického a aplikačního výzkumu v elektroenergeticecs
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (KEE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Tesarova_Evaluation.pdf340,11 kBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/35698

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD