Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorŠvantner, Michal
dc.contributor.authorMuzika, Lukáš
dc.contributor.authorHoudková Šimůnková, Šárka
dc.date.accessioned2019-12-09T11:00:21Z-
dc.date.available2019-12-09T11:00:21Z-
dc.date.issued2019
dc.identifier.citationŠVANTNER, M., MUZIKA, L., HOUDKOVÁ ŠIMŮNKOVÁ, Š. Quantitative inspection of coatings thickness by time-power transformation flash pulse thermographic method. Proceedings, 2019, roč. 27, č. 1, s. 1-4. ISSN 2504-3900.en
dc.identifier.issn2504-3900
dc.identifier.urihttp://hdl.handle.net/11025/36083
dc.description.abstractČlánek popisuje TPT (Time-Power Transformation) metodu flash-pulzní infračervené termografie. Zabývá se možností jejího využití pro kvantitativní hodnocení tloušťky povlaků žárových nástřiků. Jsou ukázány zásadní předpoklady použití metody - synchronizace a přesnost aproximace. Na příkladu jsou porovnány výsledky vyhodnocení pomocí TPT metody, měřeného signálu, derivace signálu a FFT vyhodnocení. Je ukázáno, že TPT metoda je z uvedených metod nejvhodnější pro kvantitativní hodnocení tloušťky povlaků.cs
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherMDPIen
dc.relation.ispartofseriesProceedingsen
dc.rights© MDPIen
dc.rights© Creative Commons Attribution License 4.0en
dc.subjecttermografické testovánícs
dc.subjectpovlakycs
dc.subjectinfračervené nedestruktivní testovánícs
dc.subjectflash-pulzní termografiecs
dc.titleQuantitative inspection of coatings thickness by time-power transformation flash pulse thermographic methoden
dc.title.alternativeKvantitativní inspekce tloušťky povlaků pomocí TPT flash-pulzní metodycs
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThermographic testing is an inspection method, which primary indicates a presence of discontinuities in a tested sample. Its application to coatings can indicate a presence of local thickness variations; however, it mostly does not bring a quantitative information about a thickness of the coatings. This contribution is focused on a quantification of the thermographic inspection, which would make possible an evaluation of coating thickness differences. A flash pulse thermographic testing was applied to thermally sprayed coatings. An importance of a precise synchronization of a flash-source and thermographic recording was determined. Different evaluation methods were analyzed and their comparison showed that a time-power transformation method is the most suitable for a quantification of the inspection results.en
dc.subject.translatedthermographic testingen
dc.subject.translatedcoatingsen
dc.subject.translatedinfrared non-destructive testingen
dc.subject.translatedflash-pulse thermographyen
dc.identifier.doi10.3390/proceedings2019027032
dc.type.statusPeer-revieweden
dc.identifier.obd43927352
dc.project.IDEF18_069/0010018/LabIR-PAV / Předaplikační výzkum infračervených technologiícs
Vyskytuje se v kolekcích:Články / Articles (CT3)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
msvantne proceedings-27-00032.pdf321,45 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/36083

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání