dc.identifier.citationLIŠKA, J.., JAKL, J.. On-line Monitoring of Rotor-stator Rub in Steam Turbines. In: Proceedings of the Second World Congress on Condition Monitoring (WCCM). Singapore: Research Publihing, 2019. s. 415-422. ISBN 978-981-11-0744-3.en
dc.identifier.isbn978-981-11-0744-3
dc.identifier.urihttp://hdl.handle.net/11025/36846
dc.description.abstractIn recent years, the operation of steam turbines has been associated with the occurrence of rotor-stator rub. This is because the clearences in the turbine flow paths decrease in an effort to increase the turbine efficiency. At present, detailed rubbing diagnostics is implemented as off-line analysis of measured data. The detection of the rotor-stator rub is based on analysis of vibration signals in time domain when a machine operator monitors the overall level of vibration or the vector of rotation frequency contained in the measured vibration signal. This paper deals with design and implementation of the system for online monitoring of rotor-stator rub implemented as the Rub Advanced Monitoring System (RAMS), which, in addition to detection phase, provides also localization of the place of contact occurrence, based on additional knowledge of the rotor geometry. Except the contact on the shaft, the contact between the blade tips and the stator seal can also be detected and localized. The contact is in that case accompanied by periodic impacts whose frequency for example corresponds to the product of the number of swirl brakes above blade tips and the rotation frequency. With this information obtained from standard rotor vibration signals, the rotor operation can be diagnosed in more detail and, if necessary, the turbine operation can be adapted to the current situation.en
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherResearch Publihingen
dc.relation.ispartofseriesProceedings of the Second World Congress on Condition Monitoring (WCCM)en
dc.rightsPlný text není přístupný.cs
dc.rights© Research Publihingen
dc.titleOn-line Monitoring of Rotor-stator Rub in Steam Turbinesen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.subject.translatedRotor-stator ruben
dc.subject.translatedFull spectrumen
dc.subject.translatedDiagnosticsen
dc.subject.translatedRemote monitoringen
dc.type.statusPeer-revieweden
dc.identifier.obd43928951
dc.project.IDEF16_026/0008389/LoStr: Výzkumná spolupráce pro dosažení vyšší účinnosti a spolehlivosti lopatkových strojůcs
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference Papers (KKY)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Liska_OnlineMonitoring.pdf1,22 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/36846

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD