Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorKovář, Petr
dc.contributor.authorTichý, David
dc.contributor.authorSlouka, Zdeněk
dc.date.accessioned2020-08-31T10:00:25Z-
dc.date.available2020-08-31T10:00:25Z-
dc.date.issued2019
dc.identifier.citationKOVÁŘ, P., TICHÝ, D., SLOUKA, Z. Effect of channel geometry on ion-concentration polarization-based preconcentration and desalination. Biomicrofluidics, 2019, roč. 13, č. 6, s. [1-10]. ISSN 1932-1058.en
dc.identifier.issn1932-1058
dc.identifier.uri2-s2.0-85074538452
dc.identifier.urihttp://hdl.handle.net/11025/39572
dc.format11 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherAmerican Institute of Physicsen
dc.relation.ispartofseriesBiomicrofluidicsen
dc.rightsPlný text není přístupný.cs
dc.rights© American Institute of Physicsen
dc.titleEffect of channel geometry on ion-concentration polarization-based preconcentration and desalinationen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedPolarization of the ion-selective systems results in the formation of ion-depleted and ion-concentrated zones in the electrolyte layers adjacent to the system. One can employ ion-concentration polarization for the removal of chargedlarge molecules and small ions from the flowing liquid. Removal of large molecules from the flowing solution and their local accumulation is often referred to as preconcentration, removal of small ions as desalination. Here, we study the effect of the channel geometry on the removal of charged species from their water solutions experimentally. Straight, converging, and diverging channels equipped with a pair of heterogeneous cation-exchange membranes are compared in terms of their effect on preconcentration of an observable fluorescein dye and on desalination of water solution of potassium chloride. Our results show that preconcentration of the dye is not significantly affected by the channel geometry. The distance of the preconcentration band from one of the membranes was approximately the same in all tested channel geometries. The major difference was in the location of the band within the channel, when the conical channels localized the band at one of the channel walls. The straight channel showed a slightly broader range of applicable flow rates. The semibatch desalination of 0.01M KCl solution turned out to be more efficient in conical channels, which was associated with a larger volume of the channel available for the accumulation of the concentratedsolution. Our results suggest that conical channels can be advantageously used in transforming the ion-concentrationpolarization- based semibatch desalination into a fully continuous one.en
dc.subject.translatedFluid flowen
dc.subject.translatedWater-splittingen
dc.subject.translatedIon concentration polarizationen
dc.subject.translatedFluoresceinen
dc.subject.translatedIon exchange membraneen
dc.identifier.doi10.1063/1.5124787
dc.type.statusPeer-revieweden
dc.identifier.document-number505984000006
dc.identifier.obd43929959
dc.project.IDLO1402/CENTEM+cs
Vyskytuje se v kolekcích:Články / Articles
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Slouka_Effect of channel geometry on ionconcentration polarization-based-1.pdf2,61 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/39572

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD