Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorMuzika, Lukáš
dc.contributor.authorŠvantner, Michal
dc.contributor.authorMoskal, Denys
dc.date.accessioned2020-08-31T10:00:26Z-
dc.date.available2020-08-31T10:00:26Z-
dc.date.issued2020
dc.identifier.citationMUZIKA, L., ŠVANTNER, M., MOSKAL, D. Experimental investigation of time-power transformation method for flash-pulse thermographic testing. Applied Optics, 2020, roč. 59, č. 17, s. E89-E96. ISSN 1559-128X.en
dc.identifier.issn1559-128X
dc.identifier.uri2-s2.0-85086499174
dc.identifier.urihttp://hdl.handle.net/11025/39574
dc.description.abstractčlánek se zabývá flash-pulzní termografií - metody pro termografické testování. Je popsán experimentální výzkum metody "time power transformation" pro vyhodnocení výsledků flash-pulzní termografie. Je popsán proces měření a vyhodnocení, na příkladech jsou provedeny vyhodnocení různými metodami a je ukázáno porovnání výsledků. Na příkladech jsou prezentovány výhody metody time power transformation.cs
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherOptical Society of Americaen
dc.relation.ispartofseriesApplied Opticsen
dc.rightsPlný text není přístupný.cs
dc.rights© Optical Society of Americaen
dc.subjecttermografiecs
dc.subjecttermografické testovánícs
dc.subjecttermografická inspekcecs
dc.subjectflash-pulzní termografiecs
dc.titleExperimental investigation of time-power transformation method for flash-pulse thermographic testingen
dc.title.alternativeExperimentální výzkum metody "time power transformation" pro flash pulzní termografiics
dc.typečlánekcs
dc.typearticleen
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe paper deals with flash-pulse thermography, which is one of the most used thermographic inspection methods. The method is based on flash excitation of an inspected object and an analysis of its thermal response recorded by an infrared camera. This paper deals with a time-power transformation method (P-function) for an evaluation of the flash-pulse thermography measurement. The method is based on a transformation of the measured thermalresponse using a power function of time. An adaptation of the method is introduced, and an experimental investigation of the method is presented. The method and the evaluation procedure are described. A flash-pulse inspection of an experimental sample is performed, and the results of the inspection obtained by the P-function method and by a fast Fourier transform evaluation are compared using a contrast-to-noise ratio ranking. Advantages of the P-function method resulting from its numerical outputs for an estimation of the depth of defects are described. An influence of noise reduction and data preprocessing is discusseden
dc.subject.translatedthermographyen
dc.subject.translatedthermographic testingen
dc.subject.translatedthermographic inspectionen
dc.subject.translatedflash-pulse thermographyen
dc.identifier.doi10.1364/AO.388437
dc.type.statusPeer-revieweden
dc.identifier.document-number540285800014
dc.identifier.obd43929967
dc.project.IDEF18_069/0010018/LabIR-PAV / Předaplikační výzkum infračervených technologiícs
Vyskytuje se v kolekcích:Články / Articles (CT3)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Muzika_experimental investigation of p-function thermographic testing.pdf1,91 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/39574