Název: Various aging processes in a paper-natural ester insulation system in the presence of copper and moisture
Autoři: Trnka, Pavel
Hornak, Jaroslav
Prosr, Pavel
Michal, Ondřej
Wang, Feipeng
Citace zdrojového dokumentu: TRNKA, P., HORNAK, J., PROSR, P., MICHAL, O., WANG, F. Various aging processes in a paper-natural ester insulation system in the presence of copper and moisture. IEEE Access, 2020, roč. 8, č. 2020, s. 61989-61998. ISSN 2169-3536.
Datum vydání: 2020
Nakladatel: IEEE
Typ dokumentu: článek
article
URI: 2-s2.0-85083428966
http://hdl.handle.net/11025/39583
ISSN: 2169-3536
Klíčová slova v dalším jazyce: aging;dielectrics;hydrogenation;hydrolysis;oil insulation;paper-oil insulating system;natural ester;complex permittivity
Abstrakt v dalším jazyce: This article adds more information to the problem of natural ester use as an electroinsulating uid in cellulose paper-oil systems, e.g., for use in power transformers. An accelerated thermal aging (120, 140 and 160 C) of samples consisting of cellulose paper (transformerboard), a treated natural ester (ltered, basic Al2O3, 0.53% DBPC), a copper plate and moisture was studied. Research was especially focused on the impact of moisture on the aging of the above system. Samples with three different oil moisture levels (80, 143 and 305 ppm water content) were subjected to thermal aging to display the change in a selection of properties (tan, acid number, water content). For a study of the polarization effects, broadband dielectric spectroscopy (BDS) was performed to observe the complex permittivity and conductivity dependencies on the temperature and frequency (30 C, 0.01107 Hz). Havriliak-Negami (H-N) diagrams were used to further understand the results. The degradation products during thermal aging were recognized by Fourier transform infrared (FT-IR) spectroscopy. Hydrolysis and hydrogenation occurred in the insulating system with a natural ester aged by elevated temperatures, which is in contrast to CO2 formation in the case of electric aging. The results showed an increase in the acid number, dissipation factor, and number of hydrolysis and hydrogenation products. Furthermore, changes in polarization were observed as a consequence of the thermal aging of paper-natural ester insulation system with the presence of copper and moisture.
Práva: © IEEE
Vyskytuje se v kolekcích:Články / Articles (RICE)
Články / Articles (KET)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Trnka_09050518-2.pdf1,86 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/39583

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD