Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorPajdarová, Andrea Dagmar
dc.contributor.authorKozák, Tomáš
dc.contributor.authorHubička, Zdeněk
dc.contributor.authorČada, Martin
dc.contributor.authorMareš, Pavel
dc.contributor.authorČapek, Jiří
dc.date.accessioned2020-11-02T11:00:18Z
dc.date.available2020-11-02T11:00:18Z
dc.date.issued2020
dc.identifier.citationPAJDAROVÁ, A. D., KOZÁK, T., HUBIČKA, Z., ČADA, M., MAREŠ, P., ČAPEK, J. Plasma parameters in positive voltage pulses of bipolar HiPIMS discharge determined by Langmuir probe with a sub-microsecond time resolution. Plasma sources science & Technology, 2020, roč. 29, č. 8, s. „085016-1“-„085016-11“. ISSN 0963-0252.en
dc.identifier.issn0963-0252
dc.identifier.uri2-s2.0-85092265900
dc.identifier.urihttp://hdl.handle.net/11025/39878
dc.description.abstractUrčili jsme lokální parametry plazmatu měřením Langmuirovou sondou se submikrosekundovým časovým rozlišením během kladných pulzů napětí bipolárního vysokovýkonového impulzního magnetronového výboje využívajícího nevyvážený magnetron s titanovým terčem. Efekty amplitudy kladného napěťového pulzu a zpoždění mezi koncem záporného napěťového pulzu a začátkem kladného napěťového pulzu jsou zkoumány stejně jako prostorová závislost parametrů plazmatu na třech vzdálenostech od terče. Z výsledků byly určeny hodnoty průměrného toku energie iontů během kladného napěťového pulzu na substrát. Zjistili jsme, že časové vývoje parametrů plazmatu mají podobné průběhy, které jsou nezávislé na parametrech kladných napěťových pulzů a vzdálenosti od terče, byť hodnoty parametrů plazmatu se liší. Během počáteční části kladného napěťového pulzu byly zaregistrovány vysoké rozdíly (až 200 V) mezi plazmovým a plovoucím potenciálem doprovázené vysokou teplotou elektronů (až 150 eV) a výrazným poklesem hustoty elektronů (až o jeden řád). Po této části byly rozdíly potenciálů a teplota elektronů malé (< 2 V a ≤ 1 eV). Krátké zpoždění mezi koncem záporného napěťového pulzu a začátkem kladného napěťového pulzu stejně jako vyšší amplitudy kladného napěťového pulzu mají příznivý vliv na průměrný tok energie iontů během kladného napěťového pulzu na uzemněné i izolované substráty.cs
dc.format11 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIOP Publishingen
dc.relation.ispartofseriesPlasma Sources Science & Technologyen
dc.rightsPlný text není přístupný.cs
dc.rights© IOP Publishingen
dc.subjectbipolární HiPIMScs
dc.subjectkladný napěťový pulzcs
dc.subjectdiagnostika Langmuirovou sondoucs
dc.subjectplazmový a plovoucí potenciálcs
dc.subjectelektronová hustota a teplotacs
dc.subjecttok energie iontůcs
dc.subjectnevyvážený magnetroncs
dc.titlePlasma parameters in positive voltage pulses of bipolar HiPIMS discharge determined by Langmuir probe with a sub-microsecond time resolutionen
dc.title.alternativeParametry plazmatu v kladných napěťových pulzech bipolárního HiPIMS výboje určené Langmuirovou sondou se submikrosekundovým časovým rozlišenímcs
dc.typečlánekcs
dc.typearticleen
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedWe have determined the local plasma parameters using the Langmuir probe measurements with a sub-microsecond time resolution during positive voltage pulses of a bipolar high-power impulse magnetron sputtering discharge using an unbalanced magnetron with a titanium target. The effects of the positive voltage pulse amplitude and the delay between the negative voltage pulse end and the positive voltage pulse initiation are investigated as well as the spatial dependence of the plasma parameters at three distances from the target. From the results, the values of the average energy flux of ions during the positive voltage pulse to the substrate are estimated. We have found that the time evolution of the plasma parameters has similar developments which are independent of the positive voltage pulse parameters and the distance from the target, although the values of the plasma parameters are different. During the initial part of the positive voltage pulse, a large difference (up to 200 V) between the plasma and the floating potential accompanied by a high electron temperature (up to 150 eV) and a significant decrease of electron density (up to one order of magnitude) is registered. After this part, the difference of the potentials and the electron temperature are low (< 2 V and ≤ 1 eV, respectively). The short delays between the negative voltage pulse end and the positive voltage pulse initiation as well as the higher positive voltage amplitudes have a beneficial effect on the average energy flux of ions during the positive voltage pulse to the grounded and insulated substrates.en
dc.subject.translatedbipolar HiPIMSen
dc.subject.translatedpositive voltage pulseen
dc.subject.translatedLangmuir probe diagnosticsen
dc.subject.translatedplasma and floating potentialen
dc.subject.translatedelectron density and temperatureen
dc.subject.translatedenergy flux of ionsen
dc.subject.translatedunbalanced magnetronen
dc.identifier.doi10.1088/1361-6595/aba773
dc.type.statusPeer-revieweden
dc.identifier.document-number568418000001
dc.identifier.obd43930302
dc.project.IDFV30177/Výzkum a vývoj nových pulzních plazmových technologií pro depozici pokročilých tenkovrstvých materiálůcs
Vyskytuje se v kolekcích:Články / Articles (NTIS)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
OBD20_Pajdarova,Kozak,Capek_clanek.pdf2,89 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/39878

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD