Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorJandová, Věra
dc.contributor.authorFajgar, Radek
dc.contributor.authorKupčík, Jaroslav
dc.contributor.authorPola, Josef
dc.contributor.authorSoukup, Karel
dc.contributor.authorMikysek, Petr
dc.contributor.authorKřenek, Tomáš
dc.contributor.authorKovářík, Tomáš
dc.contributor.authorStich, Theresia
dc.contributor.authorDocheva, Denitsa
dc.date.accessioned2020-11-16T11:00:21Z-
dc.date.available2020-11-16T11:00:21Z-
dc.date.issued2020
dc.identifier.citationJANDOVÁ, V., FAJGAR, R., KUPČÍK, J., POLA, J., SOUKUP, K., MIKYSEK, P. , KŘENEK, T., KOVÁŘÍK, T., STICH, T., DOCHEVA, D. Corrosion behavior of titanium silicide surface with hydrogen peroxide: Formation of sub-μm TiOx- based spheres, nanocomposite TiOx/SiOx phases, and mesoporous TiOx/SiOx network. Applied surface science, 2020, roč. 529, č. NOV 1 2020. ISSN 0169-4332.cs
dc.identifier.issn0169-4332
dc.identifier.uri2-s2.0-85087663597
dc.identifier.urihttp://hdl.handle.net/11025/41924
dc.description.abstractDosud neprozkoumaná koroze povrchu silicidu titanu (Ti5Si3) okyseleným peroxidem vodíku je zajímavá díky svému potenciálnímu využití při zlepšování osseointegrace titanových implantátů potažených silicidy titanu. Detailní charakterizace produktů koroze pomocí FTIR, Ramanovy a XP spektroskopie, elektronové mikroskopie, XRD, BET a techniky rozptylu světla umožňují rozpoznání hydratovaných nanokompozitních fází TiOx / SiOx (x≤2) složených ze segregovaných amorfních fází SiOx a sítě na bázi TiOx obsahující vazby Ti-O-Si a -O-O. ¨ Vzhled TiOx síťoví závisí na rozsahu peroxidace. Méně postupující peroxidace poskytuje submikronové kuličky na bázi Tild, které po žíhání vyvíjejí anatasová nahozena, která odolávají do teploty 800 °C. Výraznější peroxidace produkuje větší mesoporézní tělíska na bázi TiOx, která se desintegrují po působení ultrazvuku na entity o velikosti mikrometrů. Navrhovaný mechanismus povrchové koroze vyplývá z komplementárního použití analytických technik. Jednokroková produkce bioaktivních (hydratovaných TiOx a SiOx) druhů je vhodná pro další výzkum osseointegrace mírně zkorodovaných titanových implantátů potažených Ti5Si3.silicid titanu, peroxid vodíku, mikrofáze SiOx, nanofáze TiOx a SiOx, mezoporézní a mikroporézní částice na bázi TiOxcs
dc.format14 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesApplied Surface Scienceen
dc.rightsPlný text není přístupný.cs
dc.rights© Elsevieren
dc.subjectsilicid titanucs
dc.subjectperoxid vodíkucs
dc.subjectmikrofáze SiOx nanofáze TiOx a SiOxcs
dc.subjectmezoporézní a mikroporézní částice na bázi TiOxcs
dc.titleCorrosion behavior of titanium silicide surface with hydrogen peroxide: Formation of sub-μm TiOx- based spheres, nanocomposite TiOx/SiOx phases, and mesoporous TiOx/SiOx networken
dc.title.alternativeKorozní chování povrchu silicidu titanu v přítomnosti peroxidu vodíku: Tvorba sub-μm kuliček na bázi TiOx, nanokompozitních fází TiOx / SiOx a mezoporézní sítě TiOx / SiOxcs
dc.typečlánekcs
dc.typearticleen
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedSo far unexplored corrosion of titanium silicide (Ti5Si3) surface with acidified hydrogen peroxide is of interest due to its potential use in improving osseointegration of titanium implants coated by titanium silicides. Detailed examination of corrosion products by FTIR, Raman and XP spectroscopy, electron microscopy, XRD, BET and light scattering techniques allows recognition of hydrated nanocomposite TiOx/SiOx (x≤2) phases composed of segregated amorphous SiOx species and TiOx–based networks containing Ti-O-Si and -O-O- bonds. The appearance of the TiOx networks depends on the extent of peroxidation. A less progressed peroxidation yields sub- μm-sized TiOx-based spheres which upon annealing develop anatase nanograins withstanding 800° C. A more progressed peroxidation produces larger mesoporous TiOx-based bodies which disintegrate upon sonication into micrometer-sized entities. The proposed mechanism of surface corrosion is based on the complementary use of analytical techniques. The one-step production of bioactive (hydrated TiOx and SiOx) species deserves to be explored in osseointegration studies of slightly corroded Ti5Si3-coated titanium implants.en
dc.subject.translatedTitanium silicideen
dc.subject.translatedHydrogen peroxideen
dc.subject.translatedSiOx microphasesen
dc.subject.translatedTiOx and SiOx nanophasesen
dc.subject.translatedMesoporous and microporous TiOx-based particlesen
dc.identifier.doi10.1016/j.apsusc.2020.147133
dc.type.statusPeer-revieweden
dc.identifier.document-number564391100004
dc.identifier.obd43930499
Vyskytuje se v kolekcích:Články / Articles
OBD



Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/41924

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD