Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorGevorkov, Levon
dc.contributor.authorŠmídl, Václav
dc.contributor.authorSirový, Martin
dc.contributor.authorRassõlkin, Anton
dc.contributor.authorKallaste, Ants
dc.contributor.authorVaimann, Toomas
dc.date.accessioned2021-03-08T11:00:16Z-
dc.date.available2021-03-08T11:00:16Z-
dc.date.issued2020
dc.identifier.citationGEVORKOV, L. ŠMÍDL, V. SIROVÝ, M. RASSÕLKIN, A. KALLASTE, A. VAIMANN, T. Model for energy management of residential building heating system. In: 2020 27th International Workshop on Electric Drives: MPEI Department of Electric Drives 90th Anniversary (IWED 2020) : /proceedings/. Piscataway: IEEE, 2020. s. 1-4. ISBN 978-1-72814-158-9.cs
dc.identifier.isbn978-1-72814-158-9
dc.identifier.uri2-s2.0-85084451695
dc.identifier.urihttp://hdl.handle.net/11025/42793
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIEEEen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© IEEEen
dc.titleModel for energy management of residential building heating systemen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedModel based energy management and automation systems are becoming an effective solution in the field of heating systems for residential building. This paper presents a Matlab/Simulink based thermal model for a dwelling with a heating system (HS). The heating system is equipped with a centrifugal pump that has a variable speed drive allowing implementing model based control strategy. The model allows controlling the indoor climate in conformity with the defined reference point to keep the desired temperature inside the building. Also, the approach in which a model of a building is selected can simplify the control structure for thermal regulation. The paper provides an example of thermal model selection and calculation of its parameters that are designed to satisfy system requirements for a dwelling by taking into consideration the thermal comfort with minimal energy consumption. All parameters of the model can be adjusted according to the needs of building configuration and desired indoor temperature. The model helps to estimate the energy consumption of the heating system in the broad range of outdoor weather conditions.en
dc.subject.translatedpumpsen
dc.subject.translatedcentrifugal pumpen
dc.subject.translatedmatlaben
dc.subject.translatedthermal managementen
dc.subject.translatedmodellingen
dc.subject.translatedsystems simulationen
dc.identifier.doi10.1109/IWED48848.2020.9069503
dc.type.statusPeer-revieweden
dc.identifier.obd43928795
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Gevorkov_IWED2020_paper_21.pdf439,09 kBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/42793

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD