dc.date.issued2020
dc.identifier.citationŠŤASTNÝ, L. MEGO, R. PIHERA, J. HORNAK, J. Selectivity of inductive coupling for partial discharge measurement in MV cables. In: Proceedings of the 2020 International Conference on Diagnostics in Electrical Engineering (Diagnostika) : CDEE 2020. Pilsen: University of West Bohemia in Pilsen, 2020. s. 223-226. ISBN 978-1-72815-879-2, ISSN 2464-7071.cs
dc.identifier.isbn978-1-72815-879-2
dc.identifier.issn2464-7071
dc.identifier.uri2-s2.0-85094860463
dc.identifier.urihttp://hdl.handle.net/11025/42830
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUniversity of West Bohemia in Pilsenen
dc.relation.ispartofseriesProceedings of the 2020 International Conference on Diagnostics in Electrical Engineering (Diagnostika) : CDEE 2020en
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© University of West Bohemia in Pilsenen
dc.titleSelectivity of inductive coupling for partial discharge measurement in MV cablesen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe aim of this article is to verify the possibility of using inductive coupling for the on-line measurement of partial discharges MV cables. At its principle, inductive coupling records partial discharges that cause current changes over this coupling only. This natural selectivity can be used within on-line measurement, and, therefore, to restrain other partial discharges sources that can be found in MV system. That is why a new detection system based on the inductive coupling principle was designed and tested in laboratory conditions. In order to verify sensitivity and recording availability, basic partial discharges models (corona, surface, and internal) were prepared, and verifying measurement with standard PD Smart detecting system was realized. Based on measured and analyzed data, it is possible to state that this newly developed system has, at its disposal, parameters suitable for partial discharges detection.en
dc.subject.translatedpartial dischargeen
dc.subject.translatedonline diagnosticsen
dc.subject.translatedmiddlevoltageen
dc.subject.translatedcableen
dc.subject.translatedinductive couplingen
dc.identifier.doi10.1109/Diagnostika49114.2020.9214744
dc.type.statusPeer-revieweden
dc.identifier.obd43930555
Appears in Collections:Konferenční příspěvky / Conference papers (RICE)
Konferenční příspěvky / Conference Papers (KET)
OBD

Files in This Item:
File SizeFormat 
Pihera_09214744.pdf2,1 MBAdobe PDFView/Open    Request a copy


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/42830

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD