Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorTeodorescu, Horia-Nicolai
dc.contributor.editorPinker, Jiří
dc.date.accessioned2021-10-29T06:56:44Z
dc.date.available2021-10-29T06:56:44Z
dc.date.issued2021
dc.identifier.citation2021 International Conference on Applied Electronics: Pilsen, 7th – 8th September 2021, Czech Republic, p. 175-180.en
dc.identifier.isbn978–80–261–0972–3 (Print)
dc.identifier.isbn978–80–261–0973–0 (Online)
dc.identifier.issn1803–7232 (Print)
dc.identifier.issn1805–9597 (Online)
dc.identifier.urihttp://hdl.handle.net/11025/45589
dc.format6 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUniversity of West Bohemiaen
dc.rights© University of West Bohemia, 2021en
dc.subjectlékařský alarmcs
dc.subjectnositelná zařízenícs
dc.subjecttelemedicínacs
dc.subjecthnací obvodcs
dc.subjectspektracs
dc.subjectakustický měničcs
dc.subjectstandardycs
dc.titleWhat is a Good Wearable Medical Alarm Design, Anywayen
dc.typeconferenceObjecten
dc.typekonferenční příspěvekcs
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedDesigning alarms for medical equipment may seem easy, but the standards’ requirements combined with the nonlinearity of the acoustic transducers, with the difficulties of assessing the acoustic impedance of the transducer chamber, and with criteria such as power consumption and efficiency of the electric to acoustic conversion make the design challenging. We systematically analyze the related problems and discuss design solutions specifically for wearable alarms; examples are shown for an implemented alarm with usual driver. The main focus is on the power efficiency and the sound spectra of these alarms.en
dc.subject.translatedmedical alarmen
dc.subject.translatedwearable deviceen
dc.subject.translatedtelemedicineen
dc.subject.translateddriving circuiten
dc.subject.translatedspectraen
dc.subject.translatedacoustic transduceren
dc.subject.translatedstandardsen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Applied Electronics 2021
Applied Electronics 2021

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
What_is_a_Good_Wearable_Medical_Alarm_Design_Anyway_Do_we_really_know_to_design_a_wearable_medical_alarm.pdfPlný text998,86 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/45589

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.