Název: Correlation between palpatory assessment and pressure sensors in response to postural trunk tests
Autoři: Jačisko, Jakub
Stříbrný, Martin
Novák, Jakub
Busch, Andrew
Černý, Pavel
Kolář, Pavel
Kobesová, Alena
Citace zdrojového dokumentu: JAČISKO, J. STŘÍBRNÝ, M. NOVÁK, J. BUSCH, A. ČERNÝ, P. KOLÁŘ, P. KOBESOVÁ, A. Correlation between palpatory assessment and pressure sensors in response to postural trunk tests. ISOKINETICS AND EXERCISE SCIENCE, 2021, roč. 29, č. 3, s. 299-308. ISSN: 0959-3020
Datum vydání: 2021
Nakladatel: IOS Press
Typ dokumentu: článek
article
URI: 2-s2.0-85110434575
http://hdl.handle.net/11025/46286
ISSN: 0959-3020
Klíčová slova v dalším jazyce: postural stabilization;breathing;abdominal muscles;intra-abdominal pressure;Dynamic Neuromuscular Stabilization
Abstrakt v dalším jazyce: BACKGROUND: The evaluation of postural trunk muscle function is a critical component of clinical assessment in patients with musculoskeletal pain and dysfunction. Postural activation of the trunk muscles has been evaluated by various methods. This study evaluates the correlation between subjective assessment of postural trunk muscle function with an objective measurement of abdominal wall expansion. METHODS: Twenty-five healthy participants (16 women, 9 men, age 22.4 years) were assessed. The subjective assessment was performed by two experienced Dynamic Neuromuscular Stabilization (DNS) clinicians evaluating the quality of trunk stabilization using five postural stability tests through palpation and observation. Interrater reliability was determined using an intraclass correlation coefficients (ICC). Objective measurement was performed using a new device (DNS Brace) which externally measures abdominal wall pressure. Spearman rank correlations were calculated for both palpation and observation measures with DNS Brace data. RESULTS: The interrater reliability (ICC2,k) estimates demonstrated moderate reliability in palpation measures for three DNS tests: Hip flexion test, Diaphragm test, & Intra-abdominal pressure regulation test (IAPRT) (ICC = 0.645-0.707). For observation measures, good reliability was found in IAPRT (ICC = 0.835), and three tests demonstrated moderate reliability: Hip flexion test, Diaphragm test, & Breathing Stereotype (ICC = 0.577-0.695). Correlation analysis demonstrated several moderate to strong correlations between palpation and DNS brace values (Assessor 1): IAPRT, r(s) = 0.580, p = 0.002, Diaphragm test, r(s) = 0.543, p = 0.005, (Assessor 2): IAPRT, r(s) = 0.776, p < 0.001, Breathing Stereotype, r(s) = 0.625, p = 0.001, Diaphragm test, r(s) = 0.519, p = 0.008, Hip Flexion test, r(s) = 0.536, p = 0.006, and Arm Elevation test, r(s) = 0.460, p = 0.021. For observation, several moderate correlations were demonstrated with DNS brace values (Assessor 1): Arm Elevation test, r(s) = 0.472, p = 0.017, (Assessor 2) Diaphragm test, r(s) = 0.540, p = 0.005, IAPRT r(s) = 0.475, p = 0.016, Hip Flexion test, r(s) = 0.485, p = 0.014, and Arm Elevation, r(s) = 0.451, p = 0.024. CONCLUSION: Based on inter-rater reliability and DNS brace correlations with trained DNS professionals, the IAPRT, Diaphragm test, and Hip Flexion test may prove useful when assessing asymptomatic individuals. More research is needed in order to establish the utility of DNS brace and clinical testing both in asymptomatic and back pain populations. DNS tests must be supplemented by further examinations for definitive clinical decision making.
Práva: © authors
Vyskytuje se v kolekcích:Články / Articles (KFE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Jacisko J. et al. Correlation between palpatory assessment and pres.pdf780,47 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/46286

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD