Full metadata record
DC FieldValueLanguage
dc.contributor.authorAdeli, Mahdieh
dc.contributor.authorHajatipour, Majid
dc.contributor.authorYazdanpanah, Mohammad Javad
dc.contributor.authorHashemi Dezaki, Hamed
dc.contributor.authorShafieirad, Mohsen
dc.date.accessioned2022-06-06T10:00:29Z-
dc.date.available2022-06-06T10:00:29Z-
dc.date.issued2022
dc.identifier.citationADELI, M. HAJATIPOUR, M. YAZDANPANAH, MJ. HASHEMI DEZAKI, H. SHAFIEIRAD, M. Optimized cyber-attack detection method of power systems using sliding mode observer. ELECTRIC POWER SYSTEMS RESEARCH, 2022, roč. 205, č. April 2022, s. 1-12. ISSN: 0378-7796cs
dc.identifier.issn0378-7796
dc.identifier.uri2-s2.0-85122801553
dc.identifier.urihttp://hdl.handle.net/11025/47710
dc.format12 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesElectric Power Systems Researchen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Elsevieren
dc.titleOptimized cyber-attack detection method of power systems using sliding mode observeren
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThis paper investigates the problem of automatic detection of cyber-attacks in cyber-physical systems (CPSs), where some of the state variables are corrupted by an attacker. An attack detector based on a sliding mode observer (SMO) is used to estimate the state attacks. The parameter values of the SMO-based detector have a significant role in attack detection time and also in attack detection accuracy. An on-time attack detection gives the operator or the automatic attack defender enough time to react efficiently against attacks. Moreover, attacks should be detected accurately in each state variable to be handled well. Hence, a new SMO-based attack detector with parameter adjustment is addressed in this paper using an optimization algorithm. The differential evolutionary algorithm is used to optimize detection time and detection accuracy in the presence of unknown attack vectors and adjust parameters such that attacks are detected correctly and as quickly as possible. The comparison of the simulation results on the IEEE 39-bus test system based on the proposed method and those of other available methods illustrate the capability of the optimized attack detection scheme in terms of detection accuracy and detection time in the presence of unknown attack vectors.en
dc.subject.translatedattack detectionen
dc.subject.translatedcyber-physical power systemen
dc.subject.translatedadaptive sliding mode observeren
dc.subject.translateddifferential evolutionary algorithmen
dc.subject.translatedparameter adjustmenten
dc.subject.translatedoptimizationen
dc.identifier.doi10.1016/j.epsr.2021.107745
dc.type.statusPeer-revieweden
dc.identifier.document-number793762400012
dc.identifier.obd43934714
Appears in Collections:Články / Articles (RICE)
OBD

Files in This Item:
File SizeFormat 
Dezaki_1-s2.0-S0378779621007264-main-1.pdf3,08 MBAdobe PDFView/Open    Request a copy


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/47710

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD