Název: Carbohydrate Mouth Rinse Increases High but Not Low Intensity Repetitions to Failure in Resistance-Trained Males
Další názvy: Karbohydrátová ústní voda zvyšuje a zároveň nesnižuje intenzitu opakování do odmítnutí v odporovém tréninku u mužů
Autoři: Karayigit, Raci
Esar, Mustafa Can
Gur, Fatih
Sari, Cengizhan
Čepička, Ladislav
Gabryś, Tomasz
Citace zdrojového dokumentu: KARAYIGIT, R. ESAR, MC. GUR, F. SARI, C. ČEPIČKA, L. GABRYŚ, T. Carbohydrate Mouth Rinse Increases High but Not Low Intensity Repetitions to Failure in Resistance-Trained Males. Nutrients, 2022, roč. 14, č. 4, s. Nestránkováno. ISSN: 2072-6643
Datum vydání: 2022
Nakladatel: MDPI
Typ dokumentu: článek
article
URI: 2-s2.0-85124961100
http://hdl.handle.net/11025/47712
ISSN: 2072-6643
Klíčová slova: svalová vytrvalost;ergogenní doplňky;ústní voda;doplňky výživy;vysoká intenzita;vyplachování
Klíčová slova v dalším jazyce: muscular endurance;ergogenic aids;mouthwash;supplement;high intensity;rinsing
Abstrakt v dalším jazyce: Carbohydrate mouth rinsing (CMR) has been shown to enhance exercise performance. However, the influence of CMR on repetitions to failure with different intensities (40% or 80% of 1 RM) is unknown. Therefore, the purpose of this study was to examine the effects of a 6% CMR solution on muscular endurance assessed at 40% and 80% of 1 RM in resistance-trained males. Sixteen resistance-trained males (age: 25 3 years, height: 182 6 cm, body mass: 86 3 kg, body fat: 16 3%, bench press 1 RM: 106 16 kg, resistance training experience: 5 1 years) completed four conditions in random order. The four conditions consisted of ten seconds of mouth rinsing with 25 mL solutions containing either maltodextrin or placebo (sweetened water) prior to performing a bench press muscular endurance test at either 40% of 1 RM or 80% of 1 RM. Total repetitions, heart rate (HR), ratings of perceived exertion (RPE), glucose (GLU) and felt arousal (FA) were recorded for each condition. There was a significant condition by intensity interaction (p = 0.02). CMR significantly increased total repetitions compared with placebo at the higher intensity (80% of 1 RM; p = 0.04), while there was no effect at the lower intensity (p = 0.20). In addition, HR, RPE, GLU and FA did not differ between conditions or across intensities (p > 0.05). In conclusion, CMR-enhanced muscular endurance performed at higher but not lower intensities.
Práva: © authors
Vyskytuje se v kolekcích:Články / Articles (KTV)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Nutrients_02_2022.pdf842,66 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/47712

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD