Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorPittermann, Martin
dc.contributor.authorBlahnik, Vojtěch
dc.contributor.authorStraka, Miloš
dc.contributor.editorPinker, Jiří
dc.date.accessioned2022-11-04T09:08:47Z
dc.date.available2022-11-04T09:08:47Z
dc.date.issued2022
dc.identifier.citation2022 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2022, Czech Republic, p. 129-132.en
dc.identifier.isbn978-1-6654-9482-3
dc.identifier.urihttp://hdl.handle.net/11025/49866
dc.description.sponsorshipOP VVV Electrical Engineering Technologies with High-Level of Embedded Intelligence CZ.02.1.01/0.0/0.0/18_069/0009855 and under project SGS-2021-021en
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherFakulta elektrotechnická ZČUcs
dc.rights© IEEEen
dc.subjecttrakční rozvodna střídavého prouducs
dc.subjectřízení toku energiecs
dc.subjectmodel trakčního trolejového vedenícs
dc.subjectnezávislé řízení distribuce energiecs
dc.titleModel Study of Cooperating Traction Substations at 25 kV Traction Catenary without Superior Power Distribution Controlen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThis paper describes the results of the model study for traction system 25 kV / 50 Hz, which is built on an advanced traction substation with a rail active balancer and phase shifting device. The first part of this paper is described traction substation topology with a description of its properties. The following section describes the operation of the traction system in terms of interconnection with the distribution power grid. The important requirements for the behavior and used equipment of advanced traction stations are explained in more details here. The last part of this paper presents the proposed concept of control of individual traction substations, while superior power distribution control is not available. Therefore, each traction substation must have its own independent control algorithms, its behavior properties are presented and documented in the results of simulation models. In order to be able to explain the whole issue well, the created model is simplified only to the control of two independent traction substations.en
dc.subject.translatedAC traction substationen
dc.subject.translatedpower flow controlen
dc.subject.translatedtraction catenary modelen
dc.subject.translatedindependent power distribution controlen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
Konferenční příspěvky / Conference Papers (KEV)
Applied Electronics 2022
Applied Electronics 2022

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
uvod.pdfPlný text1,61 MBAdobe PDFZobrazit/otevřít
Model_Study_of_Cooperating_Traction_Substations_at_25_kV_Traction_Catenary_without_Superior_Power_Distribution_Control.pdfPlný text1,17 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/49866