Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorTalla, Jakub
dc.contributor.authorStreit, Luboš
dc.contributor.authorJanouš, Štěpán
dc.contributor.authorSuchý, Ondřej
dc.contributor.editorPinker, Jiří
dc.date.accessioned2022-11-04T12:25:30Z
dc.date.available2022-11-04T12:25:30Z
dc.date.issued2022
dc.identifier.citation2022 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2022, Czech Republic, p. 171-174.en
dc.identifier.isbn978-1-6654-9482-3
dc.identifier.urihttp://hdl.handle.net/11025/49875
dc.description.sponsorshipCZ.02.1.01/0.0/0.0/18_069/0009855, SGS-2021-021cs
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherFakulta elektrotechnická ZČUcs
dc.rights© IEEEen
dc.subjectLQR ovládánícs
dc.subjectLC filtrcs
dc.subjecttramvajcs
dc.subjectsystém skladování energiecs
dc.titleLQR Control of Input LC filter of a Tram with On-board Energy Storage Systemen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe main traction power converter of a trams is connected to DC trolley wire by input LC filter. The tram input LC filter is almost undamped resonant circuit, which is often loaded by the motor constant torque command. Sources of the input LC filter oscillation may be present on the vehicle, typically drive control influence. The source of LC filter excitation except the tram drive could be the tram’s trolley voltage caused by fluctuations in power consumption and harmonics from surrounding vehicles, and temporary loss of catenary voltage caused by crossings of insulated sections or icing on catenary. The next source could be the tram ESS, which is connected in parallel to the tram dc-link capacitor. The dynamic ESS control, which is necessary for majority of power management techniques, can also destabilize the LC filter. On the other hand, the proper ESS control could be used for LC- filter stabilization. The LQR based stabilization of LC filter using ESS is presented in this paper.en
dc.subject.translatedLQR controlen
dc.subject.translatedLC filteren
dc.subject.translatedtramen
dc.subject.translatedenergy storage systemen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
Applied Electronics 2022
Applied Electronics 2022

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
LQR_Control_of_Input_LC_filter_of_a_Tram_with_On-board_Energy_Storage_System.pdfPlný text6,48 MBAdobe PDFZobrazit/otevřít
uvod.pdfPlný text1,61 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/49875

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.