Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorDragoun, Jaroslav
dc.contributor.authorVinš, Martin
dc.contributor.authorSirový, Martin
dc.date.accessioned2022-11-28T11:00:11Z-
dc.date.available2022-11-28T11:00:11Z-
dc.date.issued2022
dc.identifier.citationDRAGOUN, J. VINŠ, M. SIROVÝ, M. Synchronous Generator Active and Reactive Power Oscilations Reduction by BESS. In 2022 International Conference on Electrical, Computer and Energy Technologies (ICECET 2022) : /proceedings/. Piscataway: IEEE, 2022. s. 1-4. ISBN: 978-1-66547-087-2cs
dc.identifier.isbn978-1-66547-087-2
dc.identifier.uri2-s2.0-85138900448
dc.identifier.urihttp://hdl.handle.net/11025/50439
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIEEEen
dc.relation.ispartofseries2022 International Conference on Electrical, Computer and Energy Technologies (ICECET 2022) : /proceedings/en
dc.rights© IEEEen
dc.titleSynchronous Generator Active and Reactive Power Oscilations Reduction by BESSen
dc.typekonferenční příspěvekcs
dc.typeConferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedIn the presented paper, we address the threats arising from the negative transient effects in the electrical grid and we propose ways how to decrease their negative effect on the synchronous generator. The proposed solution uses BESS installed in the common electrical node with the synchronous generator. The main thread arising from these transients is a continuous decrease of the turbomachinery service life, by decreasing the health of the winding insulation or by the mechanical oscillations excited by the transients, which damage the turbine. The analysis and the proposed control algorithm for the BESS have been verified by the simulation model in Simulink (MATLAB) environment. In the Simulink model, we assumed that the turbomachinery is connected to a steam turbine. As a case study, a real measured grid voltage transient has been chosen. This transient consists of a sudden drop in grid voltage magnitude. The model includes proposed control loops for the battery energy storage system and the generator itself. These are key parts affecting the stability and performance of the proposed control and it is discussed in the conclusion.en
dc.subject.translatedbattery energy storage systemen
dc.subject.translatedthermal powerplanten
dc.subject.translatedservice life improvementen
dc.identifier.doi10.1109/ICECET55527.2022.9872967
dc.type.statusPeer-revieweden
dc.identifier.obd43936687
dc.project.IDSGS-2021-021/Výzkum a vývoj perspektivních technologií v elektrických pohonech a strojích IVcs
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
Konferenční příspěvky / Conference papers (KEV)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Vins_Synchronous_Generator_Active_and_Reactive_Power_Oscilations_Reduction_by_BESS.pdf455,24 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/50439

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD