Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Vojna, Martin | |
dc.contributor.author | Ernestová, Miroslava | |
dc.contributor.author | Tonarová, Dana | |
dc.contributor.author | Junek, Lubomír | |
dc.contributor.author | Bystrianský, Jaroslav | |
dc.contributor.author | Haušild, Petr | |
dc.contributor.author | Siegl, Jan | |
dc.contributor.author | Čančura, Zdeněk | |
dc.contributor.editor | Polach, Pavel | |
dc.contributor.editor | Stuna, Lukáš | |
dc.date.accessioned | 2023-01-12T08:52:20Z | |
dc.date.available | 2023-01-12T08:52:20Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Zvyšování životnosti komponent energetických zařízení v elektrárnách. Sborník ze 14. konference: 24.– 26. září 2019. 1. vyd. Plzeň: Západočeská univerzita v Plzni, 2019, s. 93-98. | cs |
dc.identifier.isbn | 978-80-261-0885-6 | |
dc.identifier.uri | https://srni.vzuplzen.cz/wp-content/uploads/2021/04/sbornik2019.pdf | |
dc.identifier.uri | http://hdl.handle.net/11025/50880 | |
dc.description.abstract | Tento příspěvek uvádí výsledek dlouhodobé expozice heterogenních svarových spojů (HSS) teplotním cyklům v prostředí sekundárního okruhu jaderné elektrárny (JE) typu VVER. Zkoušené vzorky HSS se skládaly z uhlíkové a austenitické korozivzdorné oceli. Část vzorků byla opatřena Ni ochrannou vrstvou. Část vzorků byla v přípravcích zatížena tříbodovým ohybem pomocí speciálně vyrobených přípravků. | cs |
dc.format | 6 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | cs | cs |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.rights | © Západočeská univerzita v Plzni | cs |
dc.subject | heterogenní svarový spoj | cs |
dc.subject | VVER | cs |
dc.subject | korozivzdorná ocel | cs |
dc.title | Expozice heterogenních svarových spojů prostředí vody sekundárního okruhu | cs |
dc.title.alternative | Exposure of dissimilar metal welds to secondary water environment | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | This text presents results of long-term exposure of dissimilar metal welds (DMW) to heat cycles in VVER secondary water environment. Tested DMW were made of carbon and austenitic stainless steel. Some samples were covered by Ni protective layer. Some samples were under three-point bend load. | en |
dc.subject.translated | heterogeneous welded joint | en |
dc.subject.translated | VVER | en |
dc.subject.translated | stainless steel | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Zvyšování životnosti komponent energetických zařízení v elektrárnách 2019 Zvyšování životnosti komponent energetických zařízení v elektrárnách 2019 |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
sbornik2019-143-148.pdf | Plný text | 1,11 MB | Adobe PDF | Zobrazit/otevřít |
sbornik2019uvod_tiraz.pdf | Plný text | 3,69 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/50880
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.