dc.contributor.authorPittermann, Martin
dc.contributor.authorBlahník, Vojtěch
dc.contributor.authorStraka, Miloš
dc.date.accessioned2023-01-23T11:00:17Z-
dc.date.available2023-01-23T11:00:17Z-
dc.date.issued2022
dc.identifier.citationPITTERMANN, M. BLAHNÍK, V. STRAKA, M. Model Study of Cooperating Traction Substations at 25 kV Traction Catenary without Superior Power Distribution Control. In International Conference on Applied Electronics (AE 2022) : /proceedings/. Pilsen: University of West Bohemia, 2022. s. 129-132. ISBN: 978-1-66549-481-6 , ISSN: 1803-7232cs
dc.identifier.isbn978-1-66549-481-6
dc.identifier.issn1803-7232
dc.identifier.uri2-s2.0-85140929315
dc.identifier.urihttp://hdl.handle.net/11025/51020
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIEEEen
dc.relation.ispartofseriesInternational Conference on Applied Electronics (AE 2022) : /proceedings/en
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© IEEEen
dc.titleModel Study of Cooperating Traction Substations at 25 kV Traction Catenary without Superior Power Distribution Controlen
dc.typekonferenční příspěvekcs
dc.typeConferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThis paper describes the results of the model study for traction system 25 kV / 50 Hz, which is built on an advanced traction substation with a rail active balancer and phase shifting device. The first part of this paper is described traction substation topology with a description of its properties. The following section describes the operation of the traction system in terms of interconnection with the distribution power grid. The important requirements for the behavior and used equipment of advanced traction stations are explained in more details here. The last part of this paper presents the proposed concept of control of individual traction substations, while superior power distribution control is not available. Therefore, each traction substation must have its own independent control algorithms, its behavior properties are presented and documented in the results of simulation models. In order to be able to explain the whole issue well, the created model is simplified only to the control of two independent traction substations.en
dc.subject.translatedAC traction substationen
dc.subject.translatedpower flow controlen
dc.subject.translatedtraction catenary modelen
dc.subject.translatedindependent power distribution controlen
dc.identifier.doi10.1109/AE54730.2022.9920065
dc.type.statusPeer-revieweden
dc.identifier.obd43937065
dc.project.IDEF18_069/0009855/Elektrotechnické technologie s vysokým podílem vestavěné inteligencecs
dc.project.IDSGS-2021-021/Výzkum a vývoj perspektivních technologií v elektrických pohonech a strojích IVcs
Appears in Collections:Konferenční příspěvky / Conference Papers (KEV)
Konferenční příspěvky / Conference papers (RICE)
OBD



Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/51020

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD