Název: | Statistical Study on Human Temperature Measurement by Infrared Thermography |
Další názvy: | Statistická studie měření teploty lidí pomocí infračervené termografie |
Autoři: | Švantner, Michal Lang, Vladislav Skála, Jiří Kohlschütter, Tomáš Honner, Milan Muzika, Lukáš Kosová, Eliška |
Citace zdrojového dokumentu: | ŠVANTNER, M. LANG, V. SKÁLA, J. KOHLSCHÜTTER, T. HONNER, M. MUZIKA, L. KOSOVÁ, E. Statistical Study on Human Temperature Measurement by Infrared Thermography. SENSORS, 2022, roč. 22, č. 21, s. nestránkováno. ISSN: 1424-8220 |
Datum vydání: | 2022 |
Nakladatel: | MDPI |
Typ dokumentu: | článek article |
URI: | 2-s2.0-85141865105 http://hdl.handle.net/11025/51349 |
ISSN: | 1424-8220 |
Klíčová slova v dalším jazyce: | infrared thermography;human temperature;body temperature;thermographic measurement;infectious diseases;thermal imaging;infection control;emerging diseases;medical thermography;fever screening |
Abstrakt: | Increased temperature in humans is the symptom of many infectious diseases and it is thus an important diagnostic tool. Infrared temperature measurement methods have been developed and applied over long periods due to their advantage of non-contact and fast measurements. This study deals with a statistical evaluation of the possibilities and limitations of infrared/thermographic human temperature measurement. A short review of the use of infrared temperature measurement in medical applications is provided. Experiments and statistics-based evaluation to confirm the expected accuracy and limits of thermography-based human temperature measurement are introduced. The results presented in this study show that the standard deviation of the thermographic measurement of the eyes maximum temperature was 0.4–0.9 °C and the mean values differences from the armpit measurement were up to 0.5 °C, based on the used IR camera, even though near ideal measurement conditions and permanent blackbody correction were used. It was also shown that a certain number of outliers must be assumed in such measurements. Extended analyses including simulations of true negative/false positive, sensitivity/specificity and receiver operating characteristics (ROC) curves are presented. The statistical evaluation as well as the extended analyses show that maximum eyes temperature is more relevant than a forehead temperature examination. |
Abstrakt v dalším jazyce: | Increased temperature in humans is the symptom of many infectious diseases and it is thus an important diagnostic tool. Infrared temperature measurement methods have been developed and applied over long periods due to their advantage of non-contact and fast measurements. This study deals with a statistical evaluation of the possibilities and limitations of infrared/thermographic human temperature measurement. A short review of the use of infrared temperature measurement in medical applications is provided. Experiments and statistics-based evaluation to confirm the expected accuracy and limits of thermography-based human temperature measurement are introduced. The results presented in this study show that the standard deviation of the thermographic measurement of the eyes maximum temperature was 0.4–0.9 °C and the mean values differences from the armpit measurement were up to 0.5 °C, based on the used IR camera, even though near ideal measurement conditions and permanent blackbody correction were used. It was also shown that a certain number of outliers must be assumed in such measurements. Extended analyses including simulations of true negative/false positive, sensitivity/specificity and receiver operating characteristics (ROC) curves are presented. The statistical evaluation as well as the extended analyses show that maximum eyes temperature is more relevant than a forehead temperature examination. |
Práva: | © authors |
Vyskytuje se v kolekcích: | Články / Articles OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
SVANTNER_Statistical Study on Human Temperature Measurement by Infrared Thermography.pdf | 7,35 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/51349
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.