Název: | Analysis of flash pulse thermographic inspection parameters for quantitative measurement |
Autoři: | Švantner, Michal Muzika, Lukáš Moskovchenko, Alexey |
Citace zdrojového dokumentu: | ŠVANTNER, M. MUZIKA, L. MOSKOVCHENKO, A. ANALYSIS OF FLASH PULSE THERMOGRAPHIC INSPECTION PARAMETERS FOR QUANTITATIVE MEASUREMENT. In METAL 2021. Brno: Tanger, 2021. s. 790-794. ISBN: 978-80-87294-99-4 |
Datum vydání: | 2021 |
Nakladatel: | Tanger |
Typ dokumentu: | konferenční příspěvek ConferenceObject |
URI: | 2-s2.0-85124362552 http://hdl.handle.net/11025/51632 |
ISBN: | 978-80-87294-99-4 |
Klíčová slova v dalším jazyce: | Active thermography;thermographic testing;flash-pulse thermography;infrared non-destructive testing |
Abstrakt v dalším jazyce: | Flash-pulse thermography is a method for the detection of discontinuities or inhomogeneities in materials at their surface. It is based on excitation of inspected samples by a short pulse and analysis of its thermal response. It is basically an indicative method, however, quantitative procedures for an evaluation of defects detectability, defects depths or a thickness of coatings are also developed. The quantitative evaluation has, in general, higher demands on the accuracy of a measurement procedure. This contribution is focused on the analysis of parameters of recording of thermographic data. The influence of synchronization of a sample thermal response recording with an excitation source is analyzed. Differences between recording using a bolometric thermographic camera and a cooled detector based thermographic camera are demonstrated on flat-bottom hole samples. The results show that a high-level synchronization is crucial for the quantitative evaluation of flash-pulse thermography. It is also shown that the cooled quantum detector based thermographic cameras have better temperature response in the case of cooling process measurement and can produce higher sensitivity and lower noise records. Thus, it should be used for any quantitative flash-pulse thermography measurement, even if a bolometric detector type camera would satisfied framerates requirements. |
Práva: | © Creative Commons Attribution-ShareAlike 4.0 International License |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
SVANTNER_metal2021_analysis flash-pulse thermography quantitative.pdf | 421,82 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/51632
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.