Název: Analysis of flash pulse thermographic inspection parameters for quantitative measurement
Autoři: Švantner, Michal
Muzika, Lukáš
Moskovchenko, Alexey
Citace zdrojového dokumentu: ŠVANTNER, M. MUZIKA, L. MOSKOVCHENKO, A. ANALYSIS OF FLASH PULSE THERMOGRAPHIC INSPECTION PARAMETERS FOR QUANTITATIVE MEASUREMENT. In METAL 2021. Brno: Tanger, 2021. s. 790-794. ISBN: 978-80-87294-99-4
Datum vydání: 2021
Nakladatel: Tanger
Typ dokumentu: konferenční příspěvek
ConferenceObject
URI: 2-s2.0-85124362552
http://hdl.handle.net/11025/51632
ISBN: 978-80-87294-99-4
Klíčová slova v dalším jazyce: Active thermography;thermographic testing;flash-pulse thermography;infrared non-destructive testing
Abstrakt v dalším jazyce: Flash-pulse thermography is a method for the detection of discontinuities or inhomogeneities in materials at their surface. It is based on excitation of inspected samples by a short pulse and analysis of its thermal response. It is basically an indicative method, however, quantitative procedures for an evaluation of defects detectability, defects depths or a thickness of coatings are also developed. The quantitative evaluation has, in general, higher demands on the accuracy of a measurement procedure. This contribution is focused on the analysis of parameters of recording of thermographic data. The influence of synchronization of a sample thermal response recording with an excitation source is analyzed. Differences between recording using a bolometric thermographic camera and a cooled detector based thermographic camera are demonstrated on flat-bottom hole samples. The results show that a high-level synchronization is crucial for the quantitative evaluation of flash-pulse thermography. It is also shown that the cooled quantum detector based thermographic cameras have better temperature response in the case of cooling process measurement and can produce higher sensitivity and lower noise records. Thus, it should be used for any quantitative flash-pulse thermography measurement, even if a bolometric detector type camera would satisfied framerates requirements.
Práva: © Creative Commons Attribution-ShareAlike 4.0 International License
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
SVANTNER_metal2021_analysis flash-pulse thermography quantitative.pdf421,82 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/51632

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD