Název: | The Behavior of Cold-Curing Resin after Thermal and UV Radiation Exposures |
Autoři: | Hornak, Jaroslav Trnka, Pavel Prosr, Pavel Michal, Ondřej Kopřiva, Jiří |
Citace zdrojového dokumentu: | HORNAK, J. TRNKA, P. PROSR, P. MICHAL, O. KOPŘIVA, J. The Behavior of Cold-Curing Resin after Thermal and UV Radiation Exposures. In AIP Conference proceedings. Melville: American Institute of Physics Inc., 2023. s. "040010-1" - 040010-6". ISBN: 978-0-7354-4479-9 , ISSN: 0094-243X |
Datum vydání: | 2023 |
Nakladatel: | American Institute of Physics Inc. |
Typ dokumentu: | konferenční příspěvek ConferenceObject |
URI: | 2-s2.0-85160246132 http://hdl.handle.net/11025/52968 |
ISBN: | 978-0-7354-4479-9 |
ISSN: | 0094-243X |
Klíčová slova v dalším jazyce: | cold-cure;epoxy;UV radiation;thermal exposure |
Abstrakt v dalším jazyce: | Potting compounds are widely used in electrical engineering. One of the distinctive subgroups is the so-called cold-cure potting compounds. These potting compounds are mainly used for mechanical or photosensitive protection and are thus often exposed to extreme conditions due to their nature of use. The epoxy mixture was subjected to a separate degradation process of elevated temperature (180 °C) and UV-B radiation (peak at 302 nm, 3x20 W) for 500 h. Electrical (volume resistivity, space charge, relative permittivity, dielectric losses), mechanical (tensile strength) and optical (FTIR) methods were used to verify the degree of degradation. From the presented results it can be seen that in terms of volume resistivity there is only a minimal decrease in both cases. However, the change in dielectric behavior is evident in the relative permittivity and loss factor, especially after the glass transition temperature is exceeded in the case of thermally aged material. The different behavior is also observable in terms of space charge trapping and de-trapping. Mechanical tests showed a significant decrease in tensile strength for the thermally aged material (≥ 50 % decrease). There was also a negative change in the case of UV-B exposure, but not as pronounced (≥ 10 % decrease). The thermal oxidation and photooxidation were confirmed by presence of additional spectral bands at 1740 cm-1 and 1650 cm-1, respectively. These phenomena also resulted in typical discoloration of the samples (temperature: browning, UV-B: yellowing) after the exposure. |
Práva: | © The Author(s) |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers (RICE) Konferenční příspěvky / Conference Papers (KET) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Hornak_040010_1_5.0135805.pdf | 1,36 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/52968
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.