Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorKovář, Petr
dc.contributor.authorSmoleň, Michal
dc.contributor.authorPagáč, Jan
dc.contributor.authorKincl, Marek
dc.contributor.authorSlouka, Zdeněk
dc.date.accessioned2023-09-04T10:00:21Z-
dc.date.available2023-09-04T10:00:21Z-
dc.date.issued2023
dc.identifier.citationKOVÁŘ, P. SMOLEŇ, M. PAGÁČ, J. KINCL, M. SLOUKA, Z. Experimental 3D concentration profiles along an electrodialysis channel reveal a strong effect of natural convection. DESALINATION, 2023, roč. 548, č. FEB 15 2023, s. nestránkováno. ISSN: 0011-9164cs
dc.identifier.issn0011-9164
dc.identifier.uri2-s2.0-85143793308
dc.identifier.urihttp://hdl.handle.net/11025/53886
dc.format
dc.format10 s.cs
dc.format.mimetypeapplication/pdf
dc.language.iso
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesDESALINATIONen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelůmcs
dc.rights© Elsevieren
dc.titleExperimental 3D concentration profiles along an electrodialysis channel reveal a strong effect of natural convectionen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedElectrodialysis and electrodeionization separate ionic components from processed water solutions by applying a DC electric field on a stack of ion-exchange membranes. The ion separation indicates ionic concentration changes along the channels in the membrane modules. Simultaneously, concentration polarization at the ion-exchange membranes causes ionic concentration variations across the channels. We constructed a milifluidic cell with a diluate channel to measure spatial concentration profiles under single-path electrodialysis conditions. Desalination of 0.1 M NaCl solution showed that the concentration decreases linearly along the channel when connecting relatively low average current densities (< 30 A/m2), yielding <70 % desalination. Higher average current densities causing desalination close to 100 % produced nonlinear concentration profiles characterized by a steep linear drop followed by an almost constant and small concentration region. We show that at a current density of 50 A/m2, only one-third of the diluate channel is employed for desalination. Interestingly, uniform concentration profiles developed across the channels even at high polarization current densities. Unlike constant concentrations across the channel, we found substantial concentration variation in the vertical direction of the channel, indicating the effect of density gradients and natural convection. This effect was confirmed by optical microscopy and particle image velocimetry of this convection in stagnant solution layers. Natural convection, thus, can represent a mechanism intensifying the mass transfer from the solution bulk to the membrane surfaces.en
dc.subject.translatedelectrodialysisen
dc.subject.translatedgravityen
dc.subject.translatedconcentration profilesen
dc.subject.translatedcurrent densityen
dc.identifier.doi10.1016/j.desal.2022.116302
dc.type.status
dc.type.statusPeer-revieweden
dc.identifier.document-number904568000003
dc.identifier.obd43939952
Vyskytuje se v kolekcích:Články / Articles
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
SLOUKA_Experimental.pdf3,07 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/53886

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD