Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorOshurbekov, Safarbek
dc.contributor.authorKazakbaev, Vadim
dc.contributor.authorPrakht, Vladimir
dc.contributor.authorDmitrievskii, Vladimir
dc.contributor.authorGevorkov, Levon
dc.date.accessioned2023-12-04T11:00:24Z-
dc.date.available2023-12-04T11:00:24Z-
dc.date.issued2020
dc.identifier.citationOSHURBEKOV, S. KAZAKBAEV, V. PRAKHT, V. DMITRIEVSKII, V. GEVORKOV, L. Energy Consumption Comparison of a Single Variable-Speed Pump and a System of Two Pumps: Variable-Speed and Fixed-Speed. Applied Sciences, 2020, roč. 10, č. 24, s. 1-14. ISSN: 2076-3417cs
dc.identifier.issn2076-3417
dc.identifier.uri2-s2.0-85103860760
dc.identifier.urihttp://hdl.handle.net/11025/54920
dc.format
dc.format14 s.cs
dc.format.mimetypeapplication/pdf
dc.language.iso
dc.language.isoenen
dc.publisherMDPIen
dc.relation.ispartofseriesApplied Sciencesen
dc.rights© The Author(s)en
dc.titleEnergy Consumption Comparison of a Single Variable-Speed Pump and a System of Two Pumps: Variable-Speed and Fixed-Speeden
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe energy efficiency of a multi-pump system consisting of two low-power (0.75 kW) pumps operating in parallel mode and a single-pump mechanism (1.5 kW) is compared in this study. For this purpose, mathematical models, experimental data, and data retrieved from the manuals provided by the pump manufacturers are used. The single-pump system is fed by a single variable speed drive. A multi-pump system running in parallel mode consists of two pumps. One of them is driven by an induction motor connected directly to the electrical grid and equipped with a throttle. Another pump is actuated by an induction motor fed by a variable speed drive. The flowrate of the liquid in the multi-pump is controlled with the help of speed variation and throttling. In the case of the single-pump system the conventional speed control method is applied during the analysis. For both pump system topologies, the daily and annual energy consumption is obtained. As a result of conducted calculations, it was shown that the multi-pump provides 29.8% savings in comparison to the single-pump system in the case of a typical flowrate profile.en
dc.subject.translatedcentrifugal pumpen
dc.subject.translatedenergy eciencyen
dc.subject.translatedinduction motoren
dc.subject.translatedthrottling controlen
dc.subject.translatedvariable speed controlen
dc.identifier.doi10.3390/app10248820
dc.type.status
dc.type.statusPeer-revieweden
dc.identifier.document-number602955200001
dc.identifier.obd43940724
Vyskytuje se v kolekcích:Články / Articles (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
applsci-10-08820.pdf2,61 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/54920

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD