Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorJedlička, Pavel
dc.contributor.editorRendl, Jan
dc.date.accessioned2018-07-12T12:23:15Z-
dc.date.available2018-07-12T12:23:15Z-
dc.date.issued2018
dc.identifier.citationRENDL, Jan ed. Studentská vědecká konference: magisterské a doktorské studijní programy, sborník rozšířených abstraktů, květen 2018, Plzeň. Plzeň: Západočeská univerzita v Plzni, 2019, s. 48-49. ISBN 978-80-261-0790-3.cs
dc.identifier.isbn978-80-261-0790-3
dc.identifier.urihttp://hdl.handle.net/11025/29820
dc.identifier.urihttp://svk.fav.zcu.cz/download/sbornik_svk_2018.pdf
dc.description.sponsorshipThe work has been supported by the grant of the University of West Bohemia, project No. SGS-2016-039. Studentská vědecká konference je pořádána s podporou prostředků na specifický vysokoškolský výzkum SVK1-2018-024.cs
dc.format2 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plznics
dc.rights© Západočeská univerzita v Plznics
dc.subjectznakový jazykcs
dc.subjectsnímání pohybucs
dc.subjectdatabázecs
dc.titleSign Language Motion Capture database recorded by one deviceen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedBased on experience from above mentioned work, we tested approach using only one device to record all components at once. Specifically, we used combination of different VICON MoCap cameras and using VICON’s MX system. Different shapes and sizes of retro-reflexive markers were used for different body parts, eg. 14mm and 8mm diameter spherical markers were used for arm and head tracking, and 2.5 and 4mm diameter hemispherical markers were used for tracking facial features and finger movement. This approach seems to be very promising while it deals with most of aforementioned problems. The drawbacks of this approach is that quality of recording is dependent on high camera count and their precise layout that is subject-dependent. While all markers are tracked optically, occlusions in some signs can not be avoided and therefore it is to be dealt with during post-processing.en
dc.subject.translatedsign languageen
dc.subject.translatedmotion captureen
dc.subject.translateddatabseen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Studentská vědecká konference 2018-magisterské a doktorské studijní programy
Studentská vědecká konference 2018-magisterské a doktorské studijní programy