dc.contributor.author | Muzika, Lukáš | |
dc.contributor.author | Švantner, Michal | |
dc.contributor.editor | Kučerová, Ludmila | |
dc.contributor.editor | Jirková, Hana | |
dc.contributor.editor | Jeníček, Štěpán | |
dc.date.accessioned | 2019-10-08T12:37:00Z | - |
dc.date.available | 2019-10-08T12:37:00Z | - |
dc.date.issued | 2019 | |
dc.identifier.citation | JIRKOVÁ, Hana ed.; JENÍČEK, Štepán ed. Proceedings PING 2019: modern trends in material engineering: 10.-13.09.2019, Pilsen. 1. vyd. Plzeň: University of West Bohemia, 2019, s. 74. ISBN 978-80-261-0879-5. | en |
dc.identifier.isbn | 978-80-261-0879-5 | |
dc.identifier.uri | http://hdl.handle.net/11025/35250 | |
dc.description.sponsorship | PING 2019 is organized with the support of funds for specific university research project SVK1-2019-002. | en |
dc.format | 1 s. | cs |
dc.format.mimetype | application/PDF | |
dc.language.iso | en | en |
dc.publisher | University of West Bohemia | en |
dc.rights | © University of West Bohemia | en |
dc.subject | IRNDT | cs |
dc.subject | flash pulzní termografie | cs |
dc.subject | měření tloušťky | cs |
dc.subject | kontrola kvality | cs |
dc.title | Flash pulse phase thermography for a paint thickness determination | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | The contribution describes a fast contactless measurement of a paint thickness nonuniformity using flash pulse thermography. Specimens sprayed by a paint were thermally excited by a flash lamp and temperature responses were recorded by an infrared camera. The recorded sequences were post-processed with Fast Fourier Transform to obtain phase angles. Differences in the resulting images showed phase differences which corresponded to a paint thickness non-uniformity. Furthermore, the phases were correlated with the thickness by means of calibration curve so that the paint thickness could be determined with flash pulse phase thermography measurement. The method showed a promising potential in the contactless evaluation of the paint thickness. Average error of the thickness determination was less than 10 % for samples with paint thickness from 41 to 74 μm on AISI 304 substrate. Advantages, disadvantages and limitations of described method were discussed. | en |
dc.subject.translated | IRNDT | en |
dc.subject.translated | flash pulse thermography | en |
dc.subject.translated | thickness measurement | en |
dc.subject.translated | quality control | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Proceedings PING 2019: modern trends in material engineering Konferenční příspěvky / Conference papers (CT3) Proceedings PING 2019: modern trends in material engineering |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Muzika.pdf | Plný text | 179,76 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/35250
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.