Title: Elimination of the Leakage Inductance of the Primary Winding of an Impulse Transformer for a Contact-less Temperature Gauge
Authors: Kadlečíková, M.
Kolmačka, M.
Breza, J.
Vančo, L´.
Citation: Electroscope. 2019, č. 2.
Issue Date: 2019
Publisher: Západočeská univerzita v Plzni, Fakulta elektrotechnická
Document type: článek
article
URI: http://147.228.94.30/images/PDF/Rocnik2019/Cislo2_2019/r13c2c9.pdf
http://hdl.handle.net/11025/36523
ISSN: 1802-4564
Keywords: chemická depozice par horkým vláknem;HF CVD
Keywords in different language: hot filament chemical vapour deposition;HF CVD
Abstract in different language: We continue in reconstruction of the temperature meter with optical transmission of temperature reading in the HF CVD reactor. The parasitic inductance causes degradation of the transformer. The issue is solved by including a non-dissipative snubber that recuperates the energy from the parasitic inductance back to the power supply and allows faster demagnetization, thereby improving the transfer of energy through the transformer to its secondary winding.
Rights: Copyright © 2019 Electroscope. All Rights Reserved.
Appears in Collections:Číslo 2 (2019)
Číslo 2 (2019)

Files in This Item:
File Description SizeFormat 
Kadlečíková.pdfPlný text229,46 kBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/36523