dc.identifier.citation | ŠTORK, M.., NOVÁK, J., BROŽ, P. Cardiac mathematical models for exercise testing on treadmill ergometer. In: International Conference on Applied Electronics (AE 2019) : /proceedings/. Pilsen: University of West Bohemia, 2019. s. 161-164. ISBN 978-80-261-0813-9 , ISSN 1803-7232. | en |
dc.identifier.isbn | 978-80-261-0813-9 | |
dc.identifier.issn | 1803-7232 | |
dc.identifier.uri | 2-s2.0-85074170483 | |
dc.identifier.uri | http://hdl.handle.net/11025/36786 | |
dc.description.abstract | Cardiac output (CO) is a key parameter in the assessment of cardiac function, and its measurement is fundamental to the diagnosis, treatment, and prognostic evaluation of all heart diseases. In this paper the linear and nonlinear models for noninvasive estimation of CO are presented. The estimation is based from short examination where parameters of subject were measured up to maximal load and from these parameters the CO and stroke volume (SV) were estimated for evaluation of cardiovascular performance of the subject. This approach was used for group of twenty marathon runners. Linear and nonlinear mathematical models and samples of measuring results are also presented. | en |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | University of West Bohemia | en |
dc.relation.ispartofseries | International Conference on Applied Electronics (AE 2019) : /proceedings/ | en |
dc.rights | © University of West Bohemia in Pilsen | en |
dc.title | Cardiac mathematical models for exercise testing on treadmill ergometer | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.subject.translated | cardiac output | en |
dc.subject.translated | linear model | en |
dc.subject.translated | cubic model | en |
dc.subject.translated | non-invasive estimation | en |
dc.subject.translated | oxygen uptake | en |
dc.subject.translated | heart rate | en |
dc.subject.translated | stroke volume | en |
dc.identifier.doi | 10.23919/AE.2019.8866998 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.obd | 43926946 | |
dc.project.ID | LO1607/RICE-NETESIS - nové technologie a koncepce pro inteligentní průmyslové systémy (NETESIS) | cs |
dc.project.ID | SGS-2018-001/Výzkum a vývoj elektronických a komunikačních systémů ve vědeckých a inženýrských aplikacích | cs |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference Papers (KAE) Konferenční příspěvky / Conference papers (RICE) OBD |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Stork_Cardiac.pdf | 391,52 kB | Adobe PDF | Zobrazit/otevřít | |
IEEE Strok_08866998.pdf | 248,99 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/36786
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.