Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorZich, Jan
dc.contributor.authorGeorgiev, Vjačeslav
dc.contributor.authorHolík, Michael
dc.contributor.authorPavlíček, Vladimír
dc.contributor.authorVavroch, Ondřej
dc.date.accessioned2020-03-30T10:00:27Z-
dc.date.available2020-03-30T10:00:27Z-
dc.date.issued2019
dc.identifier.citationZICH, J., GEORGIEV, V., HOLÍK, M., PAVLÍČEK, V., VAVROCH, O. Multichannel coincidence circiut with settable threshold level for ToF AFP detector. In: 2019 27th Telecommunications Forum (TELFOR) : Proceedings of Papers. Piscataway: IEEE, 2019. s. 1-4. ISBN 978-1-72814-790-1.en
dc.identifier.isbn978-1-72814-790-1
dc.identifier.urihttp://hdl.handle.net/11025/36813
dc.description.abstractThe detectors and signal processing chains in the experimental particle physics produce the data in the order of tens GB per hour due to high rate events. The trigger module, as one of the units for signal processing in the Time-of-Flight detector, uses the MCC (Multichannel Coincidence Circuit) for data stream reduction based on the settable threshold level used for the selection of the events related to the ongoing physical experiment. In this paper the MCC design of the circuitry and firmware is described. The performance of the MCC has been verified by measurement and the results proved the proper function of the device. The next generation of the trigger module will be based on this MCC and installed on the LHC particle detector in CERN.en
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIEEEen
dc.relation.ispartofseries2019 27th Telecommunications Forum (TELFOR) : Proceedings of Papersen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© IEEEen
dc.titleMultichannel coincidence circiut with settable threshold level for ToF AFP detectoren
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.subject.translatedcoincidence circuiten
dc.subject.translateddata stream reductionen
dc.subject.translatedparticle physicsen
dc.subject.translatedtime-of-flighten
dc.subject.translatedtrigger moduleen
dc.identifier.doi10.1109/TELFOR48224.2019.8971310
dc.type.statusPeer-revieweden
dc.identifier.obd43927830
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
Konferenční příspěvky / Conference Papers (KAE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Zich_TELFOR2019_07_07.pdf667,79 kBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/36813

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD