Title: Continuous walking-beam furnace 3D zonal model and direct thermal-box barrier based temperature measurement
Other Titles: 3D zonální model průběžné krokové pece a přímě měření pomocí tepelné box-bariéry
Authors: Švantner, Michal
Študent, Josef
Veselý, Zdeněk
Citation: ŠVANTNER, M., ŠTUDENT, J., VESELÝ, Z. Continuous walking-beam furnace 3D zonal model and direct thermal-box barrier based temperature measurement. Case Studies in Thermal Engineering, 2020, roč. 18, č. APR 2020. ISSN 2214-157X.
Issue Date: 2020
Publisher: Elsevier
Document type: článek
article
URI: 2-s2.0-85083807736
http://hdl.handle.net/11025/37026
ISSN: 2214-157X
Keywords: měření teplot;průmyslové pece;tepelná box-bariéra;zonální model;numerická simulace;krokové pece;radiační přenostepla
Keywords in different language: Furnace;Walking-beam furnace;Radiation heat transfer;Numerical model;Hottel zonal method;Thermal box-barrier;Temperature measurement
Abstract: Článek popisuje metodu a implementaci 3D zonálního modelu pro výpočet tepelného procesu ohřevu vsázky v průmyslové krokové peci. Je prezentováno přímě měření teplot vsázky při průchodu pecí pomocí tepelné box-bariéry. Jsou porovnány experimentální výsledky s numerickým modele
Abstract in different language: Numerical simulation of industrial reheating furnaces belongs to important procedures for an optimization of their designand processing parameters. A 3D numerical model of a continuous gas burners heated walking-beam furnace is introduced in this paper. The main benefit of the model is a compromise between its complexity and computing speed. The model connects numerical procedures and empirical knowledge. It is based on a Hottel zonal method and a compartment based solution of heat transfer process in solids. It allows specifying charge, heating system and furnace parameters. The solution includes convective and radiative heat transfer in the furnace including a participation of a semi-transparent gaseous furnace atmosphere. A direct measurement of charge temperature course in a walking-beam furnace using thermocouples and thermal box-barrier are introduced. Comparisons of the measurement results with results of numerical simulations are presented. Connection between direct measurement in the furnace and the numerical simulation parameters is discussed. A good agreement between the theoretical and measured data shows, that the model includes the most important physical process.
Rights: © Elsevier
Appears in Collections:Články / Articles (CT3)
OBD

Files in This Item:
File SizeFormat 
Svantner_furn zone model - CSTE final.pdf1,23 MBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/37026

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD