Title: | Metody a technologie pro měření a vyhodnocení úrovně glukózy v krvi se zaměřením na flexibilní substráty |
Other Titles: | Methods and technologies for measuring and evaluating glucose level in blood with a focus on flexible substrates |
Authors: | Škarda, Jakub |
Advisor: | Michal David, Ing. |
Referee: | Šlauf Josef, Ing. |
Issue Date: | 2021 |
Publisher: | Západočeská univerzita v Plzni |
Document type: | bakalářská práce |
URI: | http://hdl.handle.net/11025/44508 |
Keywords: | diabetes mellitus;selfmonitoring glykemie;osobní glukometry;cgm;fgm;neinvazivní senzory glukózy;flexibilní substráty |
Keywords in different language: | diabetes mellitus;self-monitoring of glycemia;personal glucose meters;cgm;fgm;non-invasive glucose sensors;flexible substrates |
Abstract: | Tato bakalářská práce se zabývá metodami a technologiemi pro určení koncentrace glukózy v krvi. Zvýšená pozornost je věnována novým neinvazivním senzorům založeným na flexibilních substrátech. Nejdříve jsou popsány principy současně využívaných invazivních a minimálně invazivních metod. Zahrnuta je také charakterizace komerčně dostupných technologií a jejich zhodnocení. Následně jsou popsány potenciálně aplikovatelné metody neinvazivního charakteru. Závěr práce je věnován nově vznikajícím flexibilním senzorům, které zastupují slibné neinvazivní metody. Tyto senzory jsou zhodnoceny a porovnány s nejnovějšími komerčně rozšířenými minimálně invazivními senzory. |
Abstract in different language: | Presented bachelor thesis deals with methods and technologies for determining the blood glucose level. Increased attention is dedicated to new non-invasive sensors based on flexible substrates. At first, the principles of currently used invasive and minimally invasive methods are described. In this part, the characterization of commercially available technologies and their evaluation i also included. Thereafter, potentially applicable methods for non-invasive glucose monitoring are described. The final part of the work is devoted to the newly emerging flexible sensors, which represent promising non-invasive methods. These sensors are evaluated and compared with the latest commercially widespread minimally invasive sensors. |
Rights: | Plný text práce je přístupný bez omezení. |
Appears in Collections: | Bakalářské práce / Bachelor´s works (KET) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
BP_Skarda_Jakub.pdf | Plný text práce | 1,95 MB | Adobe PDF | View/Open |
PosudekVedoucihoSTAG.pdf | Posudek vedoucího práce | 37,33 kB | Adobe PDF | View/Open |
PosudekOponentaSTAG.pdf | Posudek oponenta práce | 54,2 kB | Adobe PDF | View/Open |
ProtokolSPrubehemObhajobySTAG.pdf | Průběh obhajoby práce | 23,82 kB | Adobe PDF | View/Open |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/44508
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.