Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorGlac, Antonín
dc.contributor.authorŠmídl, Václav
dc.contributor.authorPeroutka, Zdeněk
dc.contributor.authorHackl, Christoph M.
dc.date.accessioned2021-10-25T10:00:24Z-
dc.date.available2021-10-25T10:00:24Z-
dc.date.issued2021
dc.identifier.citationGLAC, A. ŠMÍDL, V. PEROUTKA, Z. HACKL, CHM. Dependence of IPMSM motor efficiency on parameter estimates. Sustainability, 2021, roč. 13, č. 16, s. 1-16. ISSN: 2071-1050cs
dc.identifier.issn2071-1050
dc.identifier.uri2-s2.0-85113390139
dc.identifier.urihttp://hdl.handle.net/11025/45520
dc.format16 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherMDPIen
dc.relation.ispartofseriesSustainabilityen
dc.rights© Creative Commons Attribution Licenseen
dc.titleDependence of IPMSM motor efficiency on parameter estimatesen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe efficiency of an IPMSM motor is influenced by the operating point of the machine. Conventional approaches to generate measured efficiency maps may be too expensive to use in some situations, thus it often replaced by simpler variants based on parametric models. A promising approach is to combine model-based approaches with online parameter identification methods which would allow following changes of the parameters. However, such approaches may also result in deteriorated performance if the online parameter estimation is inaccurate. We present a systematic experimental study of the influence of the parameter estimates on the efficiency of a 4.5 kW IPMSM drive and analyze the sources of inaccuracy. The first outcome of this study is that none of the tested methods performs well when the machine is fully loaded, which deteriorates overall performance. The second outcome is that the conventional maximum torque per ampere/current (MTPA/MTPC) is not an accurate optimization criterion. The overall performance of the compared methods thus heavily depends on the testing profile. When a significant part of the profile is at full load, the methods based on online estimation are unsuitable and parameters estimated offline using frequency domain provides better efficiency under the maximum torque per current control strategy.en
dc.subject.translatedrecursive least squares (RLS)en
dc.subject.translatedtorque per current ratio (TPC)en
dc.subject.translatedinterior permanent magnet synchronous motor (IPMSM)en
dc.subject.translatedmaximum torque per ampere (MTPA)en
dc.subject.translatedmaximum torque per current (MTPC)en
dc.subject.translatedflux linkage mapen
dc.subject.translateddrive efficiencyen
dc.identifier.doi10.3390/su13169299
dc.type.statusPeer-revieweden
dc.identifier.document-number689965700001
dc.identifier.obd43933310
dc.project.IDEF18_069/0009855/Elektrotechnické technologie s vysokým podílem vestavěné inteligencecs
dc.project.IDSGS-2021-021/Výzkum a vývoj perspektivních technologií v elektrických pohonech a strojích IVcs
Vyskytuje se v kolekcích:Články / Articles (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Glac_sustainability-13-09299-v2-1.pdf1,08 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/45520

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD