Název: | Economics of reusing spent nuclear fuel by Teplator for district heating applications |
Autoři: | Abushamah, Hussein Abdulkareem Sale Mašata, David Müller, Michael Škoda, Radek |
Citace zdrojového dokumentu: | ABUSHAMAH, HAS. MAŠATA, D. MÜLLER, M. ŠKODA, R. Economics of reusing spent nuclear fuel by Teplator for district heating applications. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, roč. 46, č. 5, s. 5771-5788. ISSN: 0363-907X |
Datum vydání: | 2022 |
Nakladatel: | Wiley |
Typ dokumentu: | článek article |
URI: | 2-s2.0-85120658273 http://hdl.handle.net/11025/47654 |
ISSN: | 0363-907X |
Klíčová slova v dalším jazyce: | carbon emission reduction;Czech Republic;district heating technologies;economic method;heat-only nuclear plant;spent nuclear fuel |
Abstrakt v dalším jazyce: | The Teplator is a nuclear heat-only reactor under development in the Czech Republic, which uses already irradiated spent nuclear fuel (SNF). This study aims to assess the feasibility of integrating this technology with district heating systems (DHSs) compared with other heating technologies. Therefore, the heating sector in the Czech Republic is evaluated, the need for alternative clean energy sources is explained, and some potential candidate locations for implementing the proposed technology are determined. The availability of the required SNF is investigated. An economic model based on cash flows is developed for evaluating different heat sources. The method includes the essential costs: investment, fuel, operation, maintenance, carbon emission, and additional expenses. The economics of the Teplator is calculated compared with gas, biomass, heat pump, and electric-based district heating show that Teplator has less expenditure of 55% and 42% than gas boilers and heat pumps. Moreover, 217 kg of CO2 emissions is saved per MWh compared with gas-based heating. Sensitivity analyses of interest rate, fuel price, construction cost, etc., representing variant scenarios are performed. Although in some cases, for example, when the interest rate is >10%, or 0% salvage value is assumed for Teplator, heat pumps are competitive, Teplator is feasible in many probable scenarios. |
Práva: | Plný text je přístupný v rámci univerzity přihlášeným uživatelům. © Wiley |
Vyskytuje se v kolekcích: | Články / Articles (KEP) Články / Articles (KEE) Články / Articles (RICE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Skoda_Intl J of Energy Research - 2021 - Abushamah.pdf | 3,82 MB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/47654
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.