Title: Measurement of low AC currents by the standard current probe equipped with lock-in amplifier
Authors: Švarný, Jiří
Citation: ŠVARNÝ, J. Measurement of low AC currents by the standard current probe equipped with lock-in amplifier. In Proceedings of the 2022 International Conference on Diagnostics in Electrical Engineering (Diagnostika) : CDEE 2022. Pilsen: University of West Bohemia in Pilsen, 2022. s. nestránkováno. ISBN: 978-1-66548-082-6
Issue Date: 2022
Publisher: University of West Bohemia in Pilsen
Document type: konferenční příspěvek
ConferenceObject
URI: 2-s2.0-85141363698
http://hdl.handle.net/11025/50537
ISBN: 978-1-66548-082-6
Keywords in different language: current probe;lock-in amplifier;dynamic range;current measurement;noise suppression
Abstract in different language: Most of standard current probes are intended for the measurement of medium or higher currents. Usually, due to limited dynamic range, characteristic sensitivity and inner noise of the probe, it is hardly possible to measure currents lower than 100 mA. The paper deals with the possibility to extend the dynamic range of the current probe by an additional external lock-in amplifier. The paper describes the principle of the lock-in amplifier in general and design of the laboratory fixture of lock-in amplifier based on AD630 circuit as well. The designed amplifier was used to condition the output of the Agilentll46A current probe. The experiment is described in detail. The results show that thanks to the lockin amplifier the currents even lower than 1 mA can be easily detected.
Rights: © IEEE
Appears in Collections:OBD

Files in This Item:
File SizeFormat 
Svarny_Measurement.pdf613,94 kBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/50537

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD