dc.description.abstract | Médium primárního okruhu ETE je průběžně čištěno Ti houbovým filtrem, jehož stav je mimo jiné monitorován SEM/EDS analýzou odebíraných vzorků. Složení a porozita filtru po 15 provozních kampaních byla porovnána s výchozími parametry Ti houby a odběry po 3 a 9 kampaních. Byla prokázána sorpce rozpuštěných látek i záchyt mechanických nečistot. Dlouhodobá expozice filtru v hydrotermálním prostředí média primárního okruhu se projevuje oxidací funkčního volného povrchu Ti zrn a postupným nárůstem objemu oxidických fází. Krystalizace oxidů v podobě rutilu, anatasu a ilmenitu postupně snižuje porozitu uvnitř Ti zrn. Celková porozita filtru však zůstává téměř neovlivněna. | cs |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | cs | cs |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.rights | © Západočeská univerzita v Plzni | cs |
dc.subject | Temelín | cs |
dc.subject | ETE | cs |
dc.subject | porozita | cs |
dc.subject | primární okruh | cs |
dc.subject | SVO-1 | cs |
dc.title | Změny složení a porozity zrn titanového houbového filtru média primárního okruhu SVO-1 po dlouhodobém provozu na ETE | cs |
dc.title.alternative | Composition and porosity changes of titanium grains of the filter SVO-1 depurating primary circuit media in Temelin NPP after long term operation | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | The medium of the primary circuit of the Temelín NPP is continually cleaned by a Ti sponge filter. Its condition is monitored by SEM/EDS analysis of the samples, as well. The composition and porosity of the filter after 15 operational campaigns were compared with the baseline parameters of the Ti sponge and sampling after 3 and 9 campaigns. Sorption of dissolved substances and capture of mechanical impurities was proved. Long-term exposure of the filter in the hydrothermal environment of the primary circuit medium causes oxidation of the functional free surface of Ti grains and a gradual increase of the oxidic phases volume. Crystallization of oxides in the form of rutile, anatase and ilmenite gradually decreases the porosity inside the Ti grains. However, the overall porosity of the filter remains almost unaffected. | en |
dc.subject.translated | Temelín | en |
dc.subject.translated | ETE | en |
dc.subject.translated | porosity | en |
dc.subject.translated | primary circuit | en |
dc.subject.translated | SVO-1 | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Zvyšování životnosti komponent energetických zařízení v elektrárnách 2019 Zvyšování životnosti komponent energetických zařízení v elektrárnách 2019 |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
sbornik2019uvod_tiraz.pdf | Plný text | 3,69 MB | Adobe PDF | Zobrazit/otevřít |
sbornik2019-191-194.pdf | Plný text | 400,17 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/50889
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.