Title: | Změny složení a porozity zrn titanového houbového filtru média primárního okruhu SVO-1 po dlouhodobém provozu na ETE |
Other Titles: | Composition and porosity changes of titanium grains of the filter SVO-1 depurating primary circuit media in Temelin NPP after long term operation |
Authors: | Brabec, Petr Fencl, Zdeněk Tomek, Libor |
Citation: | Zvyšování životnosti komponent energetických zařízení v elektrárnách. Sborník ze 14. konference: 24.– 26. září 2019. 1. vyd. Plzeň: Západočeská univerzita v Plzni, 2019, s. 141-144. |
Issue Date: | 2019 |
Publisher: | Západočeská univerzita v Plzni |
Document type: | konferenční příspěvek conferenceObject |
URI: | https://srni.vzuplzen.cz/wp-content/uploads/2021/04/sbornik2019.pdf http://hdl.handle.net/11025/50889 |
ISBN: | 978-80-261-0885-6 |
Keywords: | Temelín;ETE;porozita;primární okruh;SVO-1 |
Keywords in different language: | Temelín;ETE;porosity;primary circuit;SVO-1 |
Abstract: | Médium primárního okruhu ETE je průběžně čištěno Ti houbovým filtrem, jehož stav je mimo jiné monitorován SEM/EDS analýzou odebíraných vzorků. Složení a porozita filtru po 15 provozních kampaních byla porovnána s výchozími parametry Ti houby a odběry po 3 a 9 kampaních. Byla prokázána sorpce rozpuštěných látek i záchyt mechanických nečistot. Dlouhodobá expozice filtru v hydrotermálním prostředí média primárního okruhu se projevuje oxidací funkčního volného povrchu Ti zrn a postupným nárůstem objemu oxidických fází. Krystalizace oxidů v podobě rutilu, anatasu a ilmenitu postupně snižuje porozitu uvnitř Ti zrn. Celková porozita filtru však zůstává téměř neovlivněna. |
Abstract in different language: | The medium of the primary circuit of the Temelín NPP is continually cleaned by a Ti sponge filter. Its condition is monitored by SEM/EDS analysis of the samples, as well. The composition and porosity of the filter after 15 operational campaigns were compared with the baseline parameters of the Ti sponge and sampling after 3 and 9 campaigns. Sorption of dissolved substances and capture of mechanical impurities was proved. Long-term exposure of the filter in the hydrothermal environment of the primary circuit medium causes oxidation of the functional free surface of Ti grains and a gradual increase of the oxidic phases volume. Crystallization of oxides in the form of rutile, anatase and ilmenite gradually decreases the porosity inside the Ti grains. However, the overall porosity of the filter remains almost unaffected. |
Rights: | © Západočeská univerzita v Plzni |
Appears in Collections: | Zvyšování životnosti komponent energetických zařízení v elektrárnách 2019 Zvyšování životnosti komponent energetických zařízení v elektrárnách 2019 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
sbornik2019uvod_tiraz.pdf | Plný text | 3,69 MB | Adobe PDF | View/Open |
sbornik2019-191-194.pdf | Plný text | 400,17 kB | Adobe PDF | View/Open |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/50889
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.