Název: | Alternative Approach to Optical Detection of Partial Discharges in Air |
Autoři: | Šefl, Ondřej Procházka, Radek Haller, Rainer Monkman, G. J. |
Citace zdrojového dokumentu: | ŠEFL, O. PROCHÁZKA, R. HALLER, R. MONKMAN, GJ. Alternative Approach to Optical Detection of Partial Discharges in Air . In Annual Report : Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2021). Piscataway: IEEE, 2021. s. 324-327. ISBN: 978-1-66541-907-9 , ISSN: 0084-9162 |
Datum vydání: | 2021 |
Nakladatel: | IEEE |
Typ dokumentu: | konferenční příspěvek ConferenceObject |
URI: | 2-s2.0-85126022975 http://hdl.handle.net/11025/51346 |
ISBN: | 978-1-66541-907-9 |
ISSN: | 0084-9162 |
Klíčová slova v dalším jazyce: | partial discharges;electrodes;insulation;surface discharges;sensor phenomena and characterization;UHF antennas;discharges |
Abstrakt: | This article compares the standard electrical method of partial discharge detection with a novel optical detection method based on silicon photomultipliers. A third, complementary, single-loop antenna method is added to represent the ultra-high frequency method commonly used in gas-insulated switchgear/lines. A trio of air-insulated electrode designs that simulate the fundamental fault/discharge types in gaseous insulation (protrusion - corona discharge, floating conductive particle, surface discharges) are employed. Phase-resolved partial discharge activity patterns are compiled for each electrode design. The patterns are analyzed using spatial statistics and the interpretation of the obtained data trends explained by means of an example. Ultimately, the consistency and reliability of discharge detection by the optical methods for each fault/discharge type are evaluated, and suggestions for improvement are made. |
Abstrakt v dalším jazyce: | This article compares the standard electrical method of partial discharge detection with a novel optical detection method based on silicon photomultipliers. A third, complementary, single-loop antenna method is added to represent the ultra-high frequency method commonly used in gas-insulated switchgear/lines. A trio of air-insulated electrode designs that simulate the fundamental fault/discharge types in gaseous insulation (protrusion - corona discharge, floating conductive particle, surface discharges) are employed. Phase-resolved partial discharge activity patterns are compiled for each electrode design. The patterns are analyzed using spatial statistics and the interpretation of the obtained data trends explained by means of an example. Ultimately, the consistency and reliability of discharge detection by the optical methods for each fault/discharge type are evaluated, and suggestions for improvement are made. |
Práva: | Plný text je přístupný v rámci univerzity přihlášeným uživatelům. © IEEE |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers (RICE) Konferenční příspěvky / Conference Papers (KEE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
CEIDP 2021_Alternative_Approach_to_Optical_Detection_of_Partial_Discharges_in_Air.pdf | 565,22 kB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/51346
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.