Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Bělík, Milan | |
dc.contributor.author | Yuri, Lykhovyd | |
dc.contributor.author | Kuchanskyy, Vladislav | |
dc.contributor.author | Rubanenko, Olena | |
dc.date.accessioned | 2023-03-06T11:00:30Z | - |
dc.date.available | 2023-03-06T11:00:30Z | - |
dc.date.issued | 2022 | |
dc.identifier.citation | BĚLÍK, M. YURI, L. KUCHANSKYY, V. RUBANENKO, O. Phase Design and Wires Cross Section Justification of Extra High Voltage Line . In 2022 IEEE 8th International Conference on Energy Smart Systems (ESS 2022) : /Proceedings/. Piscaway: IEEE, 2022. s. 48-52. ISBN: 979-8-3503-9920-2 | cs |
dc.identifier.isbn | 979-8-3503-9920-2 | |
dc.identifier.uri | 2-s2.0-85145358838 | |
dc.identifier.uri | http://hdl.handle.net/11025/51686 | |
dc.format | 5 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | IEEE | en |
dc.relation.ispartofseries | 2022 IEEE 8th International Conference on Energy Smart Systems (ESS 2022) : /Proceedings/ | en |
dc.rights | Plný text je přístupný v rámci univerzity přihlášeným uživatelům | cs |
dc.rights | © IEEE | en |
dc.title | Phase Design and Wires Cross Section Justification of Extra High Voltage Line | en |
dc.type | konferenční příspěvek | cs |
dc.type | ConferenceObject | en |
dc.rights.access | restrictedAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | The paper presents the results of the analysis of the economic curves of overhead power lines with subsequent justification of the design of the power line. In the paper, economic curves are constructed for a line with a rated voltage of 750 kV. The cross-sections, the use of which is justified depending on the transmitted power, are determined. The analysis of the influence of design parameters on the occurrence of resonant overvoltages in non-sinusoidal overvoltages has been carried out. Three-dimensional graphs of dependences of overvoltage values on changes in the distance between phases and split wires are constructed. | en |
dc.subject.translated | economic curves | en |
dc.subject.translated | transmission line | en |
dc.subject.translated | specific discounted costs | en |
dc.subject.translated | discounting rate | en |
dc.subject.translated | autoparametric resonance | en |
dc.subject.translated | selfexcitation of even harmonics | en |
dc.subject.translated | resonance overvoltages | en |
dc.subject.translated | nonsinusoidal mode | en |
dc.identifier.doi | 10.1109/ESS57819.2022.9969287 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.obd | 43938874 | |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers (RICE) Konferenční příspěvky / Conference Papers (KEE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Phase_Design_and_Wires_Cross_Section_Justification_of_Extra_High_Voltage_Line.pdf | 1,66 MB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/51686