Název: | Optimized protection coordination of microgrids considering power quality-based voltage indices incorporating optimal sizing and placement of fault current limiters |
Autoři: | Azimi, Abolfazl Hashemi Dezaki, Hamed |
Citace zdrojového dokumentu: | AZIMI, A. HASHEMI DEZAKI, H. Optimized protection coordination of microgrids considering power quality-based voltage indices incorporating optimal sizing and placement of fault current limiters. Sustainable Cities and Society, 2023, roč. 96, č. September 2023, s. nestránkováno. ISSN: 2210-6707 |
Datum vydání: | 2023 |
Nakladatel: | Elsevier |
Typ dokumentu: | článek article |
URI: | 2-s2.0-85159369599 http://hdl.handle.net/11025/52995 |
ISSN: | 2210-6707 |
Klíčová slova v dalším jazyce: | optimal placement and sizing of fault current;limiters (FCLs);power quality voltage-based objective;voltage sag energy index (VSEI);optimal protection coordination;directional overcurrent relays (DOCRs);microgrids (MGs) |
Abstrakt v dalším jazyce: | Several solutions, such as fault current limiters (FCLs), have been utilized to mitigate the challenges of smart grids and ADNs’ protection schemes. However, less attention has been paid to simultaneously optimizing the protection coordination and power quality (PQ) concerns, incorporating the FCLs. There is a research gap in the literature in developing a method for optimal placement and impedance value of FCLs to optimize the speed of the protection systems, voltage sag energy index, and voltage sag duration. This research aims to fill such a research gap by proposing a new multi-objective optimization problem based on the optimum placement and impedance value of FCL. The proposed method is examined by implementing the distribution network of the IEEE 30-bus test system. MATLAB and DIgSILENT are linked online to simulate the protection of the smart grid and PQ voltage-based analyses and find the best solutions by the genetic algorithm (GA). The comparative analyses infer that a 13.13% improvement in criteria, e.g., operating time of relays, voltage sag energy, and voltage sag duration, is achieved by optimal placement of FCLs, beside other decision variables. |
Práva: | Plný text je přístupný v rámci univerzity přihlášeným uživatelům © Elsevier B.V. |
Vyskytuje se v kolekcích: | Články / Articles (RICE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Dezaki_1-s2.0-S2210670723002457-main.pdf | 5,32 MB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/52995
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.