Název: Selective methane chemiresistive detection using MWCNTs array decorated by metal organic framework layer
Autoři: Zabelin, Denis
Zabelina, Anna
Guselnikova, Olga
Miliutina, Elena
Kolská, Zdeňka
Štulík, Jiří
Polanský, Radek
Elashnikov, Roman
Kalachyova, Evgeniia
Švorčík, Václav
Lyutakov, Oleksiy
Citace zdrojového dokumentu: ZABELIN, D. ZABELINA, A. GUSELNIKOVA, O. MILIUTINA, E. KOLSKÁ, Z. ŠTULÍK, J. POLANSKÝ, R. ELASHNIKOV, R. KALACHYOVA, E. ŠVORČÍK, V. LYUTAKOV, O. Selective methane chemiresistive detection using MWCNTs array decorated by metal organic framework layer. Surfaces and Interfaces, 2023, roč. 40, č. August 2023, s. nestránkováno. ISSN: 2468-0230
Datum vydání: 2023
Nakladatel: Elsevier
Typ dokumentu: článek
article
URI: 2-s2.0-85163955915
http://hdl.handle.net/11025/53861
ISSN: 2468-0230
Klíčová slova v dalším jazyce: methane detection;multi-walled carbon nanotubes;metal organic framework;chemiresistive materials
Abstrakt v dalším jazyce: Methane as a main component of natural gas, but simultaneously an explosive compound with pronounced negative environmental impact. Therefore, methane should be detected with high precision and reliability. However, the inertness and non-polar nature of methane is limiting its simple detection (e.g., by a chemiresistive approach) living a gap in sensing solution. In this paper, we propose a selective chemiresistive methane sensor consisting of abundant carbon materials (multi-walled carbon nanotubes - MWCNTs) with a metal-organic framework (PCN-14). The sensor is based on decorating a non-ordered array of MWCNTs with PCN-14, which is known to have high selectivity towards methane. The methane molecules are selectively entrapped by PCN-14 pores, which significantly affect the resistance of created hybrid materials. As a result, we could detect methane under air pressure and at room temperature, with a negligible false response from other interfering gases or moisture (except hydrogen or ethane). Despite its extreme simplicity, our chemiresistive sensor does not require chemical reaction or material-destructive binding/oxidation of methane. Therefore, long operation time and sensor stability were expected and experimentally confirmed. Finally, the initial resistance of MWCNTs-PСN-14 hybrid materials was adjusted to be measurable by a portative multimeter range, which makes our approach very simple and technically undemanding.
Práva: Plný text je přístupný v rámci univerzity přihlášeným uživatelům
© Elsevier
Vyskytuje se v kolekcích:Články / Articles (RICE)
Články / Articles (KET)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Stulik_1-s2.0-S2468023023004753-main.pdf7,96 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/53861

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD