Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorJílek, Jiří
dc.contributor.authorŠtork, Milan
dc.contributor.editorPinker, Jiří
dc.date.accessioned2019-10-08T09:14:40Z
dc.date.available2019-10-08T09:14:40Z
dc.date.issued2016
dc.identifier.citation2016 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2016, Czech Republic, p.117-120.en
dc.identifier.isbn978–80–261–0601–2 (Print)
dc.identifier.isbn978–80–261–0602–9 (Online)
dc.identifier.issn1803–7232 (Print)
dc.identifier.issn1805–9597 (Online)
dc.identifier.urihttp://hdl.handle.net/11025/35202
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plznics
dc.rights© Západočeská univerzita v Plznics
dc.subjectzápěstícs
dc.subjectkrevní tlakcs
dc.subjectbiomedicínské monitorovánícs
dc.subjectměření tlakucs
dc.subjectsoftwarecs
dc.subjectodhadcs
dc.titleDetermination of systolic, mean and diastolic blood pressures with Dual cuff system is based on physiologyen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedSingle cuff automatic blood pressure (BP) measurements are subject to errors because the BP values are based on statistical estimation rather than on physiological principles. We developed a dual cuff experimental system that uses an arm cuff and a wrist cuff. The wrist cuff function is similar to auscultation. This study concentrated on the determination of systolic, diastolic and mean BP using the wrist cuff pulse waveforms and the arm cuff pressures. Fifty two BP tests from our database were used to compute blood pressures using the wrist cuff method and the single arm cuff method and the two methods were compared. Mean BP values for both methods were similar but there were important individual differences. The dual cuff method should prove to be more accurate than single cuff methods because it is based on physiological principles.en
dc.subject.translatedwristen
dc.subject.translatedblood pressureen
dc.subject.translatedbiomedical monitoringen
dc.subject.translatedpressure measurementen
dc.subject.translatedsoftwareen
dc.subject.translatedestimationen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Články / Articles (KAE)
Applied Electronics 2016
Applied Electronics 2016

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Jilek.pdfPlný text254,61 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/35202

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.