Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Štork, Milan | |
dc.contributor.author | Weissar, Petr | |
dc.contributor.author | Kosturik, Kamil | |
dc.contributor.author | Novák, Jaroslav | |
dc.contributor.author | Zeman, Václav | |
dc.contributor.editor | Pinker, Jiří | |
dc.date.accessioned | 2019-10-09T08:35:56Z | |
dc.date.available | 2019-10-09T08:35:56Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | 2016 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2016, Czech Republic, p.261-264. | en |
dc.identifier.isbn | 978–80–261–0601–2 (Print) | |
dc.identifier.isbn | 978–80–261–0602–9 (Online) | |
dc.identifier.issn | 1803–7232 (Print) | |
dc.identifier.issn | 1805–9597 (Online) | |
dc.identifier.uri | http://hdl.handle.net/11025/35294 | |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.rights | © Západočeská univerzita v Plzni | cs |
dc.subject | akcelerometry | cs |
dc.subject | pohyb nohy | cs |
dc.subject | akcelerace | cs |
dc.subject | bluetooth | cs |
dc.subject | rozpoznávání chůze | cs |
dc.subject | biomedicínské monitorování | cs |
dc.title | Use of accelerometer for walk-run or shot analysis for sport and rehabilitation purposes | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | Human movement analysis is a research field with clinical and biometrics application. It has been shown useful in the objective measurement of gait, balance, falls risk assessment and mobility monitoring. Running and/or walking are also integral activities to most athletic disciplines. From a technological point of view, biometric walk-run recognition can be categorized into three approaches: machine vision based, floor sensor based and wearable sensor based. In this paper the accelerometer-based walk-run and shot measuring system is described. The results can be used for medical and sport purposes and also for biometric identification. The electronic system and results of measurement walk-run under laboratory conditions have been presented. | en |
dc.subject.translated | accelerometers | en |
dc.subject.translated | legged locomotion | en |
dc.subject.translated | acceleration | en |
dc.subject.translated | bluetooth | en |
dc.subject.translated | gait recognition | en |
dc.subject.translated | biomedical monitoring | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Články / Articles (KAE) Applied Electronics 2016 Applied Electronics 2016 |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Stork2.pdf | Plný text | 282,54 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/35294