Title: | Calibration of Instrument Current Transformer Test Sets |
Authors: | Draxler, Karel Hlaváček, Jan Styblíková, Renata |
Citation: | 2019 International Conference on Applied Electronics: Pilsen, 10th – 11th September 2019, Czech Republic, p.43-46. |
Issue Date: | 2019 |
Publisher: | Západočeská univerzita v Plzni |
Document type: | konferenční příspěvek conferenceObject |
URI: | http://hdl.handle.net/11025/35511 |
ISBN: | 978–80–261–0812–2 (Online) 978–80–261–0813–9 (Print) |
ISSN: | 1803–7232 (Print) 1805-9597 (Online) |
Keywords: | přístrojový proudový transformátor;kalibrace;poměrová chyba;fázový posun |
Keywords in different language: | instrument current transformer;calibration;ratio error;phase displacement |
Abstract in different language: | The paper presents the basic layout for instrument current transformer calibration using comparative method with a standard. The error difference is evaluated using electronic transformer test sets. Calibrating procedure of these systems using error simulation is also described. In conclusion, results obtained using described procedure are presented. |
Rights: | © Západočeská univerzita v Plzni |
Appears in Collections: | Applied Electronics 2019 Applied Electronics 2019 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Draxler.pdf | Plný text | 134,54 kB | Adobe PDF | View/Open |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/35511